{"paper":{"title":"Effect of scanning acceleration on the leakage signal in magnetic flux leakage type of non-destructive testing","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"","cross_cats":[],"primary_cat":"physics.app-ph","authors_text":"Fawzi Belblidia, Ian M. Cameron, Johann Sienz, Lintao Zhang, Neil R.Pearson, Paul D. Ledger, Peter Charlton","submitted_at":"2019-05-03T11:52:32Z","abstract_excerpt":"This novel work investigates the influence of the inspection system acceleration on the leakage signal in magnetic flux leakage type of non-destructive testing. The research is addressed both through designed experiments and simulations. The results showed that the leakage signal, represented by using peak to peak value, decreases between 20% and 30% under acceleration. The simulation results indicated that the main reason for the decrease is due to the difference in the distortion of the magnetic field for cases with and without acceleration, which is the result of the different eddy current "},"claims":{"count":0,"items":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"1905.01131","kind":"arxiv","version":1},"verdict":{"id":null,"model_set":{},"created_at":null,"strongest_claim":"","one_line_summary":"","pipeline_version":null,"weakest_assumption":"","pith_extraction_headline":""},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"}