Performance of the ATLAS Muon Drift-Tube Chambers at High Background Rates and in Magnetic Fields
classification
⚛️ physics.ins-det
hep-ex
keywords
chambersatlasdrift-tubehighmagneticmuonperformancearticle
read the original abstract
The ATLAS muon spectrometer uses drift-tube chambers for precision tracking. The performance of these chambers in the presence of magnetic field and high radiation fluxes is studied in this article using test-beam data recorded in the Gamma Irradiation Facility at CERN. The measurements are compared to detailed predictions provided by the Garfield drift-chamber simulation programme.
This paper has not been read by Pith yet.
Forward citations
Cited by 1 Pith paper
-
A 24-Channel Ultra-Low-Noise Preamplifier for dN/dx Measurements with Drift Tube Detectors
A 24-channel three-stage SiGe preamplifier achieves 0.35 nV/sqrt(Hz) voltage noise density, 21.11 mV/fC charge gain, 542 MHz bandwidth, 0.14 fC ENC, and SNR of 73 in He:iC4H10 gas for dN/dx measurements in drift tubes.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.