Pith. sign in

REVIEW 2 cited by

MKID development for SuperSpec: an on-chip, mm-wave, filter-bank spectrometer

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1211.1652 v1 pith:5HFNL3QS submitted 2012-11-07 astro-ph.IM

classification astro-ph.IM
keywords kidsmicrostripmm-wavespectralsuperspecwilldesigndesigned
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

SuperSpec is an ultra-compact spectrometer-on-a-chip for millimeter and submillimeter wavelength astronomy. Its very small size, wide spectral bandwidth, and highly multiplexed readout will enable construction of powerful multibeam spectrometers for high-redshift observations. The spectrometer consists of a horn-coupled microstrip feedline, a bank of narrow-band superconducting resonator filters that provide spectral selectivity, and Kinetic Inductance Detectors (KIDs) that detect the power admitted by each filter resonator. The design is realized using thin-film lithographic structures on a silicon wafer. The mm-wave microstrip feedline and spectral filters of the first prototype are designed to operate in the band from 195-310 GHz and are fabricated from niobium with at Tc of 9.2K. The KIDs are designed to operate at hundreds of MHz and are fabricated from titanium nitride with a Tc of 2K. Radiation incident on the horn travels along the mm-wave microstrip, passes through the frequency-selective filter, and is finally absorbed by the corresponding KID where it causes a measurable shift in the resonant frequency. In this proceedings, we present the design of the KIDs employed in SuperSpec and the results of initial laboratory testing of a prototype device. We will also briefly describe the ongoing development of a demonstration instrument that will consist of two 500-channel, R=700 spectrometers, one operating in the 1-mm atmospheric window and the other covering the 650 and 850 micron bands.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Spectral Data-cube Cleaning for CCAT Deep Spectroscopic Survey. I. Effect of correlated noise and filtering on the power spectrum

    astro-ph.GA 2026-07 conditional novelty 6.0 of 10

    The EoR-Spec Filter-and-Bin pipeline suppresses atmospheric 1/f noise by about four orders of magnitude and recovers the [CII]+CO power spectrum above k ~ 0.1 Mpc^-1, but suppresses large-scale modes below 20% transfe...

  2. Delensing Degree-Scale $B$-Mode Polarization with High-Redshift Line Intensity Mapping

    astro-ph.CO 2019-08 conditional novelty 6.0 of 10

    High-redshift line intensity mapping could add about 11 percent to CMB-S4 delensing performance, but only if line-of-sight density modes survive foreground removal.

Pith tools