Pith. sign in

REVIEW 1 cited by

Study and mitigation of spurious electron emission from cathodic wires in noble liquid time projection chambers

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1801.07231 v2 pith:73N44XQ7 submitted 2018-01-22 physics.ins-det

classification physics.ins-det
keywords emissionelectronliquidwiresdetectorsfieldsspurioussurface
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

Noble liquid radiation detectors have long been afflicted by spurious electron emission from their cathodic electrodes. This phenomenon must be understood and mitigated in the next generation of liquid xenon (LXe) experiments searching for WIMP dark matter or neutrinoless double beta decay, and in the large liquid argon (LAr) detectors for the long-baseline neutrino programmes. We present a systematic study of this spurious emission involving a series of slow voltage-ramping tests on fine metal wires immersed in a two-phase xenon time projection chamber with single electron sensitivity. Emission currents as low as $10^{-18}$ A can thus be detected by electron counting, a vast improvement over previous dedicated measurements. Emission episodes were recorded at surface fields as low as $\sim$10 kV/cm in some wires and observed to have complex emission patterns, with average rates of 10-200 counts per second (c/s) and outbreaks as high as $\sim$10$^6$ c/s. A fainter, less variable type of emission was also present in all untreated samples. There is evidence of a partial conditioning effect, with subsequent tests yielding on average fewer emitters occurring at different fields for the same wire. We find no evidence for an intrinsic threshold particular to the metal-LXe interface which might have limited previous experiments up to fields of at least 160 kV/cm. The general phenomenology is not consistent with enhanced field emission from microscopic filaments, but it appears instead to be related to the quality of the wire surface in terms of corrosion and the nature of its oxide layer. This study concludes that some surface treatments, in particular nitric acid cleaning for stainless steel wires, can bringing about at least order-of-magnitude improvements in overall electron emission rates, and this should help the next generation of detectors achieve the required electrostatic performance.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. MOTION, a liquid xenon time projection chamber platform for high voltage technologies in dark matter detectors

    physics.ins-det 2026-08 conditional novelty 5.0 of 10

    A new 70 kg liquid xenon test stand, MOTION, is constructed and commissioned for studying high-voltage breakdown and electrode surfaces, but its 200 kV physics program is still planned.

Pith tools