Pith. sign in

REVIEW 3 cited by

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1903.03663 v3 pith:SFVDIDKP submitted 2019-03-08 astro-ph.IM physics.ins-det

G. Gallina , P. Giampa , F. Retiere , J. Kroeger , G. Zhang , M. Ward , P. Margetak , G. Lic
show 143 more authors
T. Tsang L. Doria S. Al Kharusi M. Alfaris G. Anton I.J. Arnquist I. Badhrees P.S. Barbeau D. Beck V. Belov T. Bhatta J. Blatchford J. P. Brodsky E. Brown T. Brunner G. F. Cao L. Cao W. R. Cen C. Chambers S. A. Charlebois M. Chiu B. Cleveland M. Coon A. Craycraft J. Dalmasson T. Daniels L. Darroch S. J. Daugherty A. De St. Croix A. Der Mesrobian-Kabakian R. DeVoe J. Dilling Y. Y. Ding M. J. Dolinski A. Dragone J. Echevers M. Elbeltagi L. Fabris D. Fairbank W. Fairbank J. Farine S. Feyzbakhsh R. Fontaine P. Gautam G. Giacomini R. Gornea G. Gratta E. V. Hansen M. Heffner E. W. Hoppe J. Ho{ss}l A. House M. Hughes Y. Ito A. Iverson A. Jamil M. J. Jewell X. S. Jiang A. Karelin L. J. Kaufman D. Kodroff T. Koffas R. Krucken A. Kuchenkov K. S. Kumar Y. Lana A. Larson B.G. Lenardo D. S. Leonarda S. Lik Z. Li C. Licciardi Y. H. Linw P. Lv R. MacLellan T. McElroy M. Medina-Peregrina T. Michel B. Mong D. C. Moore K. Murray P. Nakarmi R. J. Newby Z. Ning O. Njoya F. Nolet O. Nusair K. Odgers A. Odian M. Oriunno J. L. Orrell G. S. Ortega I. Ostrovskiy C. T. Overman S. Parent A. Piepkez A. Pocar J.-F. Pratte D. Qiu V. Radeka E. Raguzin S. Rescia M. Richman A. Robinson T. Rossignol P. C. Rowson N. Roy R. Saldanha S. Sangiorgio K. Skarpaas VIII A. K. Soma G. St-Hilaire V. Stekhanov T. Stiegler X. L. Sun M. Tarka J. Todd T. Tolba T. I. Totev R. Tsang F. Vachon V. Veeraraghavan G. Visser J.-L. Vuilleumier M. Wagenpfeil M. Walent Q. Wang J. Watkins M. Weber W. Wei L. J. Wen U. Wichoski S. X. Wu W. H. Wu X. Wu Q. Xia H. Yang L. Yang Y.-R. Yen O. Zeldovich J. Zhao Y. Zhou T. Ziegler
This is my paper · ORCID
classification astro-ph.IMphysics.ins-det
keywords textnexohamamatsuvuv4reportsipmsvoltageavalanches
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Sensitivity of nEXO to $^{136}$Xe Charged-Current Interactions: Background-free Searches for Solar Neutrinos and Fermionic Dark Matter

    nucl-ex 2025-06 conditional novelty 6.0 of 10

    A new delayed-coincidence tag from 136Cs isomers could let the nEXO detector reject backgrounds down to 10^-9 and measure CNO solar neutrinos, the 7Be neutrino energy, and sub-MeV fermionic dark matter.

  2. Performance of FBK VUV-HD3 and HPK VUV4 SiPMs in the Light-only Liquid Xenon (LoLX) Detector

    physics.ins-det 2025-10 unverdicted novelty 5.0 of 10

    In-situ comparison in liquid xenon finds HPK VUV4 SiPMs detect 33–38% less scintillation light than FBK VUV-HD3 SiPMs, attributed to surface shadowing at oblique photon incidence.

  3. Canadian Contributions to the Search for Neutrinoless Double Beta Decay

    nucl-ex 2025-06 unverdicted

    A review article that details past and present Canadian contributions to neutrinoless double beta decay searches and their theoretical interpretation.

Pith tools