Pith. sign in

REVIEW

New Test of Modulated Electron Capture Decay of Hydrogen-Like $^{142}$Pm Ions: Precision Measurement of Purely Exponential Decay

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1907.06920 v2 pith:NS7JUYLQ submitted 2019-07-16 nucl-ex

classification nucl-ex
keywords decayexponentialamplitudeanalysisbeencaptureelectronhydrogen-like
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

An experiment addressing electron capture (EC) decay of hydrogen-like $^{142}$Pm$^{60+}$ ions has been conducted at the experimental storage ring (ESR) at GSI. The decay appears to be purely exponential and no modulations were observed. Decay times for about 9000 individual EC decays have been measured by applying the single-ion decay spectroscopy method. Both visually and automatically analysed data can be described by a single exponential decay with decay constants of 0.0126(7) s$^{-1}$ for automatic analysis and 0.0141(7) s$^{-1}$ for manual analysis. If a modulation superimposed on the exponential decay curve is assumed, the best fit gives a modulation amplitude of merely 0.019(15), which is compatible with zero and by 4.9 standard deviations smaller than in the original observation which had an amplitude of 0.23(4).