Pith. sign in

REVIEW 1 cited by

Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2105.13829 v2 pith:4TESSJDL submitted 2021-05-28 physics.ins-det astro-ph.IMhep-ex

classification physics.ins-detastro-ph.IMhep-ex
keywords darwindetectorxenonxenoscopefacilitycontrolcryogenicdemonstrator
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and other rare interactions. It will operate a 50 t liquid xenon detector, with 40 t in the time projection chamber (TPC). To inform the final detector design and technical choices, a series of technological questions must first be addressed. Here we describe a full-scale demonstrator in the vertical dimension, Xenoscope, with the main goal of achieving electron drift over a 2.6 m distance, which is the scale of the DARWIN TPC. We have designed and constructed the facility infrastructure, including the cryostat, cryogenic and purification systems, the xenon storage and recuperation system, as well as the slow control system. We have also designed a xenon purity monitor and the TPC, with the fabrication of the former nearly complete. In a first commissioning run of the facility without an inner detector, we demonstrated the nominal operational reach of Xenoscope and benchmarked the components of the cryogenic and slow control systems, demonstrating reliable and continuous operation of all subsystems over 40 days. The infrastructure is thus ready for the integration of the purity monitor, followed by the TPC. Further applications of the facility include R&D on the high voltage feedthrough for DARWIN, measurements of electron cloud diffusion, as well as measurements of optical properties of liquid xenon. In the future, Xenoscope will be available as a test platform for the DARWIN collaboration to characterise new detector technologies.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. MOTION, a liquid xenon time projection chamber platform for high voltage technologies in dark matter detectors

    physics.ins-det 2026-08 conditional novelty 5.0 of 10

    A new 70 kg liquid xenon test stand, MOTION, is constructed and commissioned for studying high-voltage breakdown and electrode surfaces, but its 200 kV physics program is still planned.

Pith tools