REVIEW 2 cited by
Results from the Baksan Experiment on Sterile Transitions (BEST)
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
abstract
The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos, $\nu_{e}$, observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the \textit{gallium anomaly}, which could be interpreted as evidence for oscillations between $\nu_e$ and sterile neutrino ($\nu_s$) states. A 3.414-MCi \nuc{51}{Cr} $\nu_e$ source was placed at the center of two nested Ga volumes and measurements were made of the production of \nuc{71}{Ge} through the charged current reaction, \nuc{71}{Ga}($\nu_e$,e$^-$)\nuc{71}{Ge}, at two average distances. The measured production rates for the inner and the outer targets respectively are ($54.9^{+2.5}_{-2.4}(\mbox{stat})\pm1.4 (\mbox{syst})$) and ($55.6^{+2.7}_{-2.6}(\mbox{stat})\pm1.4 (\mbox{syst})$) atoms of \nuc{71}{Ge}/d. The ratio ($R$) of the measured rate of \nuc{71}{Ge} production at each distance to the expected rate from the known cross section and experimental efficiencies are $R_{in}=0.79\pm0.05$ and $R_{out}= 0.77\pm0.05$. The ratio of the outer to the inner result is 0.97$\pm$0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20-24\% lower than expected, thus reaffirming the anomaly. These results are consistent with $\nu_e \rightarrow \nu_s$ oscillations with a relatively large $\Delta m^2$ ($>$0.5 eV$^2$) and mixing sin$^2 2\theta$ ($\approx$0.4).
Forward citations
Cited by 2 Pith papers
-
A possible solution to the gallium anomaly moving beyond the leptonic wave function factorization
A non-factorized amplitude treatment with a fitted sign-changing nuclear transition density reduces the predicted νe-71Ga capture rate by ~20%, absorbing the gallium anomaly without new physics.
-
Boomerang mechanism explaining the excess radio background
A two-stage mechanism where relic neutrinos convert to dark neutrinos in the early universe and later decay into photon states can explain the ARCADE 2 excess radio background while evading neutrino magnetic moment bounds.
Discussion (0). Continue with ORCID to comment.