Pith. sign in

REVIEW 1 cited by

Calibration of the Upgraded ALICE Inner Tracking System

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2302.00433 v1 pith:MKMTWOGV submitted 2023-02-01 physics.ins-det

classification physics.ins-det
keywords alicecalibrationsystemdatadetectorexperimentinnerits2
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

The ALICE Experiment has replaced its Inner Tracking System with a 7-layer pixel-only tracker made out of more than 24000 monolithic active pixel sensor chips, in order to fulfill the requirements of the physics program of the LHC Run 3. The upgraded Inner Tracking System (ITS2) has been installed in the ALICE experiment during the LHC long shutdown 2 and has started to take data with the beginning of Run 3 in July 2022, with proton-proton collisions at $\sqrt{s}$ = 13.6 TeV. With its 12.5 billion pixels it is the largest pixel detector installed in a high energy physics experiment to date. To guarantee stable operation and a consistently high data quality, a regular calibration of the detector has to be performed. The main part of the calibration program consists of a tuning and subsequent measurement of the pixel thresholds and a determination of the noisy channels. In particular the complexity of the threshold scan depends linearly on the number of pixels, which is why the threshold scan of the ITS2 is an unprecedented challenge. This work describes the architecture of the calibration framework, which has been developed using the detector control system of the ITS2 and the ALICE data processing layer. Results of first threshold and noise calibrations done in situ are shown as well.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. CMOS Image Sensors for CEvNS Detection at Nuclear Reactors

    physics.ins-det 2026-08 conditional novelty 5.0 of 10

    A model-based feasibility study claims a ~100 g CMOS image sensor array at a reactor can detect CEvNS within 7 to 50 days using fast frame rates and active shielding.

Pith tools