arxiv 2309.14803 v2 pith:KIWSENIE submitted 2023-09-26 astro-ph.IM

classification astro-ph.IM
keywords chwpmechanismrotationangularaperturecryogenicdesignpolarization
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

We present the requirements, design and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background (CMB) polarization experiment at Parque Astron\'{o}mico Atacama in northern Chile that covers a wide range of angular scales using both small (0.42 m) and large (6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric $1/f$ noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to $\sim$50 K to reduce detector thermal loading. Under normal operation the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism's vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 $\mu$rad$\sqrt{\mathrm{s}}$. During a cooldown, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. QUIJOTE scientific results - XX. Commissioning and First Results from the Thirty and Forty Gigahertz Instrument (TFGI)

    astro-ph.IM 2026-08 conditional novelty 5.0 of 10

    TFGI commissioning data yield 8.3 microkelvin per degree polarization sensitivity with two 31 GHz detectors, extrapolated to 1 microkelvin per degree for the full 29-detector array after 5.7 years.

  2. The Simons Observatory: Validation of reconstructed power spectra from simulated filtered maps for the Small Aperture Telescope survey

    astro-ph.CO 2025-02 conditional novelty 5.0 of 10

    This validation study finds that a transfer-function power spectrum estimator recovers unbiased cosmological parameters, including the tensor-to-scalar ratio r, in simulations of the first year of Simons Observatory s...