Pith. sign in

REVIEW 2 cited by

Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2402.04473 v2 pith:HJCBEAF3 submitted 2024-02-06 physics.ins-det hep-ex

classification physics.ins-dethep-ex
keywords detectorenergyinductancekineticphononresolutionsubstratearchitecture
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the NEXUS low-background facility at Fermilab for characterization and evaluation of this detector architecture's efficacy for a dark matter search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470 nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of $2.1\pm0.2$ eV, a factor of two better than the current state-of-the-art, enabled by millisecond-scale quasiparticle lifetimes. However, due to the sub-percent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to $\sigma_E=318 \pm 28$ eV. We further model the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, as well as the observed noise spectra, both of which impact the baseline resolution of the sensor.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Dark Matter-Electron Detectors for Dark Matter-Nucleon Interactions

    hep-ph 2024-12 conditional novelty 7.0 of 10

    Electron-sensitive superconducting detectors are simultaneously sensitive to dark matter-nucleon interactions, yielding new bounds on MeV-scale hadrophilic dark matter.

  2. Broadband phonon production from axion absorption

    hep-ph 2024-11 conditional novelty 7.0 of 10

    Random nuclear spin orientations break momentum conservation, so axion absorption in crystals excites phonons across the whole Brillouin zone, yielding a broadband detection rate proportional to the phonon density of states.

Pith tools