Pith. sign in

REVIEW 1 cited by

Bayesian self-calibration and imaging in Very Long Baseline Interferometry

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2407.14873 v1 pith:3EWFSO6G submitted 2024-07-20 astro-ph.IM

classification astro-ph.IM
keywords imagingself-calibrationbayesiandatagainmethodantenna-basedimage
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Self-calibration methods with the CLEAN algorithm have been widely employed in Very Long Baseline Interferometry (VLBI) data processing in order to correct antenna-based amplitude and phase corruptions present in the data. However, human interaction during the conventional CLEAN self-calibration process can impose a strong effective prior, which in turn may produce artifacts within the final image and hinder the reproducibility of final results. In this work, we aim to demonstrate a combined self-calibration and imaging method for VLBI data in a Bayesian inference framework. The method corrects for amplitude and phase gains for each antenna and polarization mode by inferring the temporal correlation of the gain solutions. We use Stokes I data of M87 taken with the Very Long Baseline Array (VLBA) at 43GHz, pre-calibrated using the rPICARD CASA-based pipeline. For antenna-based gain calibration and imaging, we use the Bayesian imaging software resolve. To estimate gain and image uncertainties, we use a Variational Inference method. We obtain a high-resolution M87 Stokes I image at 43GHz in conjunction with antenna-based gain solutions using our Bayesian self-calibration and imaging method. The core with counter-jet structure is better resolved, and extended jet emission is better described compared to the CLEAN reconstruction. Furthermore, uncertainty estimation of the image and antenna-based gains allows us to quantify the reliability of the result. Our Bayesian self-calibration and imaging method is able to reconstruct robust and reproducible Stokes I images and gain solutions with uncertainty estimation by taking into account the uncertainty information in the data.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Multiobjective optimization for scattering mitigation and scattering screen reconstruction in VLBI observations of the Galactic Center

    astro-ph.IM 2025-04 conditional novelty 6.0 of 10

    A multiobjective optimization method jointly reconstructs the intrinsic image and the scattering screen in VLBI data, recovering a simulated Sgr A* ring at 86 GHz and the screen velocity at 230 GHz.

Pith tools