Pith. sign in

REVIEW 1 cited by

Measurement of Charge and Light Yields for ¹²⁷Xe L-Shell Electron Captures in Liquid Xenon

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2109.11487 v2 pith:2FS4WXUD submitted 2021-09-23 physics.ins-det hep-ex

Measurement of Charge and Light Yields for ¹²⁷Xe L-Shell Electron Captures in Liquid Xenon

classification physics.ins-det hep-ex
keywords betaresponsedarkdecaydecaysl-shellmattersigma
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Dark matter searches using dual-phase xenon time-projection chambers (LXe-TPCs) rely on their ability to reject background electron recoils (ERs) while searching for signal-like nuclear recoils (NRs). ER response is typically calibrated using $\beta$-decay sources, such as tritium, but these calibrations do not characterize events accompanied by an atomic vacancy, as in solar neutrino scatters off inner shell electrons. Such events lead to emission of X-rays and Auger electrons, resulting in higher electron-ion recombination and thus a more NR-like response than inferred from $\beta$-decay calibration. We present a cross-calibration of tritium $\beta$-decays and $^{127}$Xe electron-capture decays (which produce inner-shell vacancies) in a small-scale LXe-TPC and give the most precise measurements to date of light and charge yields for the $^{127}$Xe L-shell electron-capture in liquid xenon. We observe a 6.9$\sigma$ (9.2$\sigma$) discrepancy in the L-shell capture response relative to tritium $\beta$-decays, measured at a drift field of 363 $\pm$ 14 V/cm (258 $\pm$ 13 V/cm), when compared to simulations tuned to reproduce the correct $\beta$-decay response. In dark matter searches, use of a background model that neglects this effect leads to overcoverage (higher limits) for background-only multi-kiloton-year exposures, but at a level much less than the 1-$\sigma$ experiment-to-experiment variation of the 90\% C.L. upper limit on the interaction rate of a 50 GeV/$c^2$ dark matter particle.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Dark Matter implications from the LZ, PandaX-4T and XENONnT Data

    hep-ph 2025-12 conditional novelty 6.0

    High-energy recoil excesses in LZ and XENONnT can be fit by velocity-dependent or inelastic dark matter at up to 4σ local significance, but the significance vanishes when xenon double-electron-capture charge yields ar...