Pith. sign in

REVIEW 1 cited by

Development of High Granular Neutron Time-of-Flight Detector for the BM@N experiment

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2309.09610 v2 pith:7ZQIQ4JP submitted 2023-09-18 hep-ex physics.ins-det

classification hep-exphysics.ins-det
keywords neutronwillazimuthaldetectordetectorsflowgranularhgnd
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

The HGND (High Granular Neutron Detector) is developed for the BM@N (Baryonic Matter at Nuclotron) experiment on the extracted beam of the Nuclotron at JINR, Dubna. The HGND will be used to measure the azimuthal flow of neutrons produced with energies ranging from 300 to 4000 MeV in heavy-ion collisions at beam energies of 2--4 AGeV. The azimuthal flow of charged particles will be measured using the BM@N magnet spectrometer. The data on the azimuthal flow of neutrons will shed light on the study of the high-density Equation of State (EoS) of isospin-symmetric nuclear matter, which is crucial for studying astrophysical phenomena such as neutron stars and their mergers. The HGND has a highly granular structure with approximately 2000 plastic scintillation detectors (cells), each measuring 4$\times$4$\times$2.5 cm$^3$. These detectors are arranged in 16 layers, with 121 detectors in each layer, and are subdivided by copper absorber plates with a thickness of 3 cm. The light from each cell is detected with SiPM (Silicon Photomultiplier) with an active area of 6$\times$6 mm$^2$. Developed multi-channel TDC board based on the Kintex FPGA chip with a bin width of 100 ps will be used to perform precise timestamp and amplitude measurement using Time-over-Threshold (ToT) method. Good spatial resolution due to the high granularity together with a cell's time resolution of 100-150 ps ensures neutron reconstruction with good energy resolution. The design of the detector as well as the results from test measurements and simulations have been presented.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. The Highly-Granular Time-of-Flight Neutron Detector for the BM@N experiment

    hep-ex 2024-11 conditional novelty 5.0 of 10

    Simulations show that a new time-of-flight neutron detector with 121 scintillator cells per layer and two layout options can identify and reconstruct neutrons from Bi+Bi collisions at 3A GeV with about 70% purity and ...

Pith tools