Pith. sign in

REVIEW 1 cited by

A plastic scintillator array for reactor based anti-neutrino studies

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1806.04421 v2 pith:GJJV2SAM submitted 2018-06-12 physics.ins-det hep-ex

classification physics.ins-dethep-ex
keywords reactorbackgroundscintillatordetectorismranplasticanti-neutrinoarray
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring applications. A prototype detector called mini-ISMRAN, which consists of 16$\%$ of ISMRAN, has been setup for studying the detector response, background rates and event characterization in the reactor and non-reactor environment. The data acquisition system based on waveform digitizers is being used for pulse processing and event triggering. Monte-Carlo based simulations using GEANT4 are performed to optimize lead (Pb) and borated polyethylene (BP) shielding for background reduction and to study the positron, neutron and $\gamma$-ray response in the ISMRAN detector. Characterization of plastic scintillator detectors with known radioactive sources is done for energy, timing and position measurements. Using the energy summation and bar multiplicity selection, coincident events from $\mathrm{{}^{60}Co}$ decay are reconstructed in non-reactor environment. Results from background measurements using various detectors are quantified in reactor ON and OFF condition. The shielding of 10 cm Pb and 10 cm BP along with the requirement of hits in multiple bars, reduces the uncorrelated background in reactor ON condition.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Sensitivity study of a sapphire detector using Coherent Elastic Neutrino-Nucleus Scattering process

    hep-ph 2025-02 conditional novelty 5.0 of 10

    Projected sensitivities for the proposed ICNSE sapphire detector show it could constrain new scalar and vector mediator masses at reactor sites, though its neutrino magnetic moment and weak mixing angle reach would be modest.

Pith tools