Pith. sign in

REVIEW 2 cited by

Polarization Calibration of the FAST L-band 19-beam Receiver: I. On-axis Mueller Matrix Parameters

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2411.18763 v1 pith:PMXXPFN7 submitted 2024-11-27 astro-ph.IM

Polarization Calibration of the FAST L-band 19-beam Receiver: I. On-axis Mueller Matrix Parameters

classification astro-ph.IM
keywords polarizationparametersmuellermatrixbeamobservationson-axisbeams
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

We present the polarization calibration of the 19-beam receiver at 1420 MHz within the full illumination of the Five-hundred-meter Aperture Spherical Telescope from October 2018 to March 2023. We perform spider observations to characterize the on-axis Mueller matrix of the central beam. The calibrated polarization percentage and polarization angle of a source with strong linear polarization emission are about 0.2\% and 0.5$^{\circ}$. Several parameters of the central-beam Mueller matrix show time variability from months to years, suggesting relatively frequent polarization calibrations are needed. We obtain the Mueller matrix parameters of the 18 off-center beams with the combination of on-the-fly observations and spider observations. The polarization calibration provides consistent fractional Stokes parameters of the 19 beams, although the Mueller matrix parameters of the off-center beams are not as accurate as those of the central beam. The Mueller matrix parameters of the central beam do not show a strong dependence on the reflector surface. However, we notice different off-center Mueller matrix parameters between the eastern and western sides of the reflector surface. We provide average parameters of the 19-beam Mueller matrices which should be applicable to observations from 2020 to 2022 with several caveats. After applying the average parameters, on-axis fractional linear polarization measurements $\gtrsim$ 10\% and on-axis fractional circular polarization measurements $\gtrsim$ 1.5\% can be considered high-confidence detections. For sources with weak polarization, timely polarization calibrations using spider observations are required.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Detecting Parity-Violating Gravitational Wave Backgrounds with Pulsar Polarization Arrays

    gr-qc 2025-11 unverdicted novelty 7.0

    Cross-correlating pulsar timing and polarimetry isolates the circular polarization of isotropic stochastic GW backgrounds and shares the Hellings-Downs angular pattern.

  2. Searching for axion dark matter conversion spectral lines in neutron star magnetospheres with FAST

    astro-ph.HE 2026-06 unverdicted novelty 4.0

    No axion conversion lines detected from two X-ray dim isolated neutron stars with FAST, setting g_aγγ ≲ 5×10^{-12} GeV^{-1} for masses 4.14-6.20 μeV, the tightest ACL-method constraint in this range.