Pith. sign in

REVIEW 2 cited by

High-Stability Single-Ion Clock with $5.5\times10^{-19}$ Systematic Uncertainty

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2504.13071 v2 pith:PVOQTW72 submitted 2025-04-17 physics.atom-ph quant-ph

classification physics.atom-phquant-ph
keywords clocksystematictimes10uncertaintyfieldfractionalfrequencylogic
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

We report a single-ion optical atomic clock with fractional frequency uncertainty of $5.5\times10^{-19}$ and fractional frequency stability of $3.5 \times10^{-16}/\sqrt{\tau/\mathrm{s}}$, based on quantum logic spectroscopy of a single $^{27}$Al$^+$ ion. A co-trapped $^{25}$Mg$^+$ ion provides sympathetic cooling and quantum logic readout of the $^{27}$Al$^+$ $^1$S$_0\leftrightarrow^3$P$_0$ clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous $^{27}$Al$^+$ clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the RF ion trap, eliminating systematic uncertainty due to field orientation.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Bound-state beta decay of tritium: Path to first observation and novel approach to direct neutrino mass measurement

    hep-ph 2026-07 conditional novelty 7.0 of 10

    Tritium bound-state beta decay could be seen in 3He de-excitation photons, and neutrino mass read from Doppler broadening of those emission lines.

  2. Frequency reproducibility of solid-state Th-229 nuclear clocks

    physics.atom-ph 2025-07 accept novelty 7.0 of 10

    The 229Th:CaF2 nuclear clock transition frequency is reproducible to 280 Hz (1.4e-13) between two differently doped crystals over four months at the zero-shift temperature of 195 K.

Pith tools