Split-cavity tuning of a rectangular axion haloscope operating around 8.4 GHz

classification physics.ins-det hep-ex
keywords aroundaxiontuninghaloscopedarkmatterrangetechnique
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The axion haloscope is the currently most sensitive method to probe the vanishingly small coupling of this prominent Dark Matter candidate to photons. To scan a sizeable axion Dark Matter parameter space, the cavities that make up the haloscope need to be tuned efficiently. In this article, we describe a novel technique to tune axion haloscopes around $8.4$~GHz in a purely mechanical manner without the use of dielectrics. We achieve tuning by introducing a gap along the cavity geometry. A quality factor reduction of less than 20\% is achieved experimentally for a tuning range of around 600~MHz at room temperature and at cryogenic temperatures for around 300~MHz. A larger tuning range would require an improved alignments mechanism. We present the results of a corresponding prototype and outline prospects to further develop this technique.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. The VORTEX cavity for the RADES axion haloscope

    physics.ins-det 2026-07 conditional novelty 5.0

    A split-cylinder axion haloscope tunes continuously from 9 to 8.2 GHz with modest Q loss, operates at millikelvin temperatures, and its TM010 field profile passes bead-pull verification.