Measurement of SiPM Dark Currents and Annealing Recovery for Fluences Expected in ePIC Calorimeters at the Electron-Ion Collider

classification physics.ins-det hep-exnucl-ex
keywords epicdamageradiationsipmsipmsannealinganticipatedcalorimeter
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Silicon photomultipliers (SiPMs) will be used to read out all calorimeters in the ePIC experiment at the Electron-Ion Collider (EIC). A thorough characterization of the radiation damage expected for SiPMs under anticipated EIC fluences is essential for accurate simulations, detector design, and effective operational strategies. In this study, we evaluate radiation damage for the specific SiPM models chosen for ePIC across the complete fluence range anticipated at the EIC, $10^8$ to $10^{12}$ 1-MeV $n_{\mathrm{eq}}$/cm$^2$ per year, depending on the calorimeter location. The SiPMs were irradiated using a 64 MeV proton beam provided by the University of California, Davis 76" Cyclotron. We measured the SiPM dark-current as a function of fluence and bias voltage and investigated the effectiveness of high-temperature annealing to recover radiation damage. These results provide a comprehensive reference for the design, simulation, and operational planning of all ePIC calorimeter systems.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Calibration of an Irradiated Prototype for the EIC Zero-Degree Calorimeter

    physics.ins-det 2025-12 unverdicted novelty 5.0

    An irradiated ZDC prototype for the EIC can be calibrated channel-by-channel with cosmic rays, keeping signal-to-noise above 5 for minimum ionizing particles despite SiPM damage.