pith. sign in

arxiv: 1210.4645 · v1 · pith:WY5GMUDTnew · submitted 2012-10-17 · ❄️ cond-mat.mes-hall · quant-ph

Dispersive Readout of a Few-Electron Double Quantum Dot with Fast rf Gate-Sensors

classification ❄️ cond-mat.mes-hall quant-ph
keywords quantumchargedispersivereadoutdetectorsdoublefew-electrongate-sensing
0
0 comments X
read the original abstract

We report the dispersive charge-state readout of a double quantum dot in the few-electron regime using the in situ gate electrodes as sensitive detectors. We benchmark this gate-sensing technique against the well established quantum point contact (QPC) charge detector and find comparable performance with a bandwidth of 10 MHz and an equivalent charge sensitivity of 6.3 x 10-3 e/ \sqrt Hz. Dispersive gate-sensing alleviates the burden of separate charge detectors for quantum dot systems and promises to enable readout of qubits in scaled-up arrays.