arxiv: 1707.08145 · v1 · ★pith:RO6MFZTMnew · submitted 2017-07-25 · ⚛️ physics.ins-det
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
show 277 more authors
read the original abstract
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $\nu$-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ. This will give sensitivity to WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background. DarkSide-20k could then extend its operation to a decade, increasing the exposure to 200 t yr, reaching a sensitivity of $7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass.
This paper has not been read by Pith yet.
Forward citations
Cited by 4 Pith papers
Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.
-
Characterization of argon recoils at the keV scale with ReD and ReD+
hep-ex 2026-02 unverdicted novelty 4.0
New measurements of argon's ionization yield for nuclear recoils extend coverage to 2 keV and show higher yields at lower energies than prior models.
-
Liquid argon purification and purity monitoring: apparatus and first results
physics.ins-det 2026-04 unverdicted novelty 3.0
A liquid argon purification system reached 0.25 ppb O2-equivalent impurity levels corresponding to 1.2 ms electron lifetime at 500 V/cm.
-
Liquid argon purification and purity monitoring: apparatus and first results
physics.ins-det 2026-04 unverdicted novelty 3.0
A new 13-liter liquid argon test stand achieved 0.25 ppb impurity concentration and 1.5 ms electron lifetime.
-
A radon emanation measurement system at the Carleton Noble Liquid Detector Laboratory
physics.ins-det 2026-04 unverdicted novelty 2.0
A calibrated radon emanation counter was constructed at the COLD Lab and applied to measure material emanation and nitrogen gas purity for the DEAP-3600 experiment.
discussion (0)