Pith. sign in

REVIEW 1 cited by

Objective evaluation metrics for automatic classification of EEG events

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1712.10107 v3 pith:B76XUB6F submitted 2017-12-29 cs.LG eess.SPstat.ML

classification cs.LGeess.SPstat.ML
keywords metricsdetectionevaluationperformancesingleacceptanceapplicationsdemonstrate
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

The evaluation of machine learning algorithms in biomedical fields for applications involving sequential data lacks standardization. Common quantitative scalar evaluation metrics such as sensitivity and specificity can often be misleading depending on the requirements of the application. Evaluation metrics must ultimately reflect the needs of users yet be sufficiently sensitive to guide algorithm development. Feedback from critical care clinicians who use automated event detection software in clinical applications has been overwhelmingly emphatic that a low false alarm rate, typically measured in units of the number of errors per 24 hours, is the single most important criterion for user acceptance. Though using a single metric is not often as insightful as examining performance over a range of operating conditions, there is a need for a single scalar figure of merit. In this paper, we discuss the deficiencies of existing metrics for a seizure detection task and propose several new metrics that offer a more balanced view of performance. We demonstrate these metrics on a seizure detection task based on the TUH EEG Corpus. We show that two promising metrics are a measure based on a concept borrowed from the spoken term detection literature, Actual Term-Weighted Value (ATWV), and a new metric, Time-Aligned Event Scoring (TAES), that accounts for the temporal alignment of the hypothesis to the reference annotation. We also demonstrate that state of the art technology based on deep learning, though impressive in its performance, still needs significant improvement before it meets very strict user acceptance criteria.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. A foundation model with multi-variate parallel attention to generate neuronal activity

    cs.LG 2025-06 conditional novelty 6.0 of 10

    MVPFormer, a transformer with disentangled content, time, and channel attention, achieves expert-level zero-shot seizure detection on 50 unseen patients and near-SOTA results on speech decoding, alongside the largest ...

Pith tools