Pith. sign in

REVIEW 2 cited by

CsI(Tl) Pulse Shape Discrimination with the Belle II Electromagnetic Calorimeter as a Novel Method to Improve Particle Identification at Electron-Positron Colliders

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2007.09642 v2 pith:NBZKFBYD submitted 2020-07-19 physics.ins-det hep-ex

classification physics.ins-dethep-ex
keywords pulseshapediscriminationcalorimeterparticlesimulationbellecomparisons
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

This paper describes the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron-positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $\gamma$, $\mu^+$, $\pi^\pm$, $K^\pm$ and $p/\bar{p}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K_L^0$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Measurement of the CP asymmetry in $D^+ \to \pi^+ \pi^0$ decays at Belle II

    hep-ex 2025-06 accept novelty 5.0 of 10

    The new world-best measurement of the CP asymmetry in D+ -> pi+ pi0 decays is (-1.8 +/- 0.9 +/- 0.1)%, consistent with zero and with the Standard Model.

  2. Measurement of the time-integrated $CP$ asymmetry in $D^0\to\pi^0\pi^0$ decays at Belle II

    hep-ex 2025-05 accept novelty 5.0 of 10

    Belle II measures A_CP(D0 -> pi0 pi0) = (0.30 ± 0.72 ± 0.20)%, consistent with no CP violation and with the previous Belle measurement.

Pith tools