Pith. sign in

REVIEW 1 cited by

Characterization of a CdZnTe detector for a low-power CubeSat application

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2204.00475 v2 pith:JAANNAI6 submitted 2022-04-01 astro-ph.IM astro-ph.HE

classification astro-ph.IMastro-ph.HE
keywords mathrmenergyresolutiondetectoremphread-outasicbeen
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

We report spectral and imaging performance of a pixelated CdZnTe detector custom designed for the \emph{MeVCube} project: a small Compton telescope on a CubeSat platform. \emph{MeVCube} is expected to cover the energy range between $200\;\mathrm{keV}$ and $4\;\mathrm{MeV}$, with performance comparable to the last generation of larger satellites. In order to achieve this goal, an energy resolution of few percent in full width at half maximum (FWHM) and a $3$-D spatial resolution of few millimeters for the individual detectors are needed. The severe power constraints present in small satellites require very low power read-out electronics for the detector. Our read-out is based on the VATA450.3 ASIC developed by \emph{Ideas}, with a power consumption of only $0.25\;\mathrm{mW/channel}$, which exhibits good performance in terms of dynamic range, noise and linearity. A $2.0\;\mathrm{cm} \times 2.0\;\mathrm{cm} \times 1.5\;\mathrm{cm}$ CdZnTe detector, with a custom $8 \times 8$ pixel anode structure read-out by a VATA450.3 ASIC, has been tested. A preliminary read-out system for the cathode, based on a discrete \emph{Amptek} A250F charge sensitive pre-amplifier and a DRS4 ASIC, has been implemented. An energy resolution around $3\%$ FWHM has been measured at a gamma energy of $662\;\mathrm{keV}$; at $200\;\mathrm{keV}$ the average energy resolution is $6.5\%$, decreasing to $\lesssim 2\%$ at energies above $1\;\mathrm{MeV}$. A $3$-D spatial resolution of $\approx 2\,\mathrm{mm}$ is achieved.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Searching for Dark Matter with MeVCube

    hep-ph 2025-01 conditional novelty 4.0 of 10

    Using Fisher forecasting, the author shows that a 2U to 12U MeVCube CubeSat could probe new dark matter parameter space for evaporating primordial black holes and MeV-scale decaying or annihilating dark matter.

Pith tools