REVIEW 3 cited by
GenerateCT: Text-Conditional Generation of 3D Chest CT Volumes
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
read the original abstract
GenerateCT, the first approach to generating 3D medical imaging conditioned on free-form medical text prompts, incorporates a text encoder and three key components: a novel causal vision transformer for encoding 3D CT volumes, a text-image transformer for aligning CT and text tokens, and a text-conditional super-resolution diffusion model. Without directly comparable methods in 3D medical imaging, we benchmarked GenerateCT against cutting-edge methods, demonstrating its superiority across all key metrics. Importantly, we evaluated GenerateCT's clinical applications in a multi-abnormality classification task. First, we established a baseline by training a multi-abnormality classifier on our real dataset. To further assess the model's generalization to external data and performance with unseen prompts in a zero-shot scenario, we employed an external set to train the classifier, setting an additional benchmark. We conducted two experiments in which we doubled the training datasets by synthesizing an equal number of volumes for each set using GenerateCT. The first experiment demonstrated an 11% improvement in the AP score when training the classifier jointly on real and generated volumes. The second experiment showed a 7% improvement when training on both real and generated volumes based on unseen prompts. Moreover, GenerateCT enables the scaling of synthetic training datasets to arbitrary sizes. As an example, we generated 100,000 3D CTs, fivefold the number in our real set, and trained the classifier exclusively on these synthetic CTs. Impressively, this classifier surpassed the performance of the one trained on all available real data by a margin of 8%. Last, domain experts evaluated the generated volumes, confirming a high degree of alignment with the text prompt. Access our code, model weights, training data, and generated data at https://github.com/ibrahimethemhamamci/GenerateCT
Forward citations
Cited by 3 Pith papers
-
Structured Spectral Graph Learning for Anomaly Classification in 3D Chest CT Scans
A graph neural network with spectral convolution over axial slice triplet nodes improves multi-label chest CT anomaly classification on two public datasets.
-
Structured Spectral Graph Representation Learning for Multi-label Abnormality Analysis from 3D CT Scans
A graph-of-slice-triplets encoder with spectral convolution outperforms 3D CNN/Transformer baselines on multi-label chest CT abnormality classification and transfers to report generation and abdominal CT.
-
From large language models to multimodal AI: A scoping review on the potential of generative AI in medicine
A PRISMA-ScR scoping review of 144 studies finds the field shifting from text-only LLMs to multimodal AI in medicine, with evaluation and data diversity still the main bottlenecks.
Discussion (0). Continue with ORCID to comment.