Pith. sign in

REVIEW 1 cited by

rPPG-MAE: Self-supervised Pre-training with Masked Autoencoders for Remote Physiological Measurement

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2306.02301 v1 pith:7LDH54RL submitted 2023-06-04 cs.CV

classification cs.CV
keywords methodsself-supervisedphysiologicalimportantproposedrppg-maesignalsamounts
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Remote photoplethysmography (rPPG) is an important technique for perceiving human vital signs, which has received extensive attention. For a long time, researchers have focused on supervised methods that rely on large amounts of labeled data. These methods are limited by the requirement for large amounts of data and the difficulty of acquiring ground truth physiological signals. To address these issues, several self-supervised methods based on contrastive learning have been proposed. However, they focus on the contrastive learning between samples, which neglect the inherent self-similar prior in physiological signals and seem to have a limited ability to cope with noisy. In this paper, a linear self-supervised reconstruction task was designed for extracting the inherent self-similar prior in physiological signals. Besides, a specific noise-insensitive strategy was explored for reducing the interference of motion and illumination. The proposed framework in this paper, namely rPPG-MAE, demonstrates excellent performance even on the challenging VIPL-HR dataset. We also evaluate the proposed method on two public datasets, namely PURE and UBFC-rPPG. The results show that our method not only outperforms existing self-supervised methods but also exceeds the state-of-the-art (SOTA) supervised methods. One important observation is that the quality of the dataset seems more important than the size in self-supervised pre-training of rPPG. The source code is released at https://github.com/linuxsino/rPPG-MAE.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. CodePhys: Robust Video-based Remote Physiological Measurement through Latent Codebook Querying

    cs.CV 2025-02 conditional novelty 6.0 of 10

    CodePhys casts remote heart-rate measurement as a code query task: a video encoder produces features matched to a learned codebook of clean PPG waveforms, and a pre-trained decoder reconstructs the pulse.

Pith tools