Pith. sign in

REVIEW 2 cited by

The Gallium Anomaly

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2306.03299 v1 pith:GND5KYQR submitted 2023-06-05 nucl-ex nucl-th

classification nucl-exnucl-th
keywords neutrinoanomalybestexperimentscountingknownresultssource
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

In order to test the end-to-end operations of gallium solar neutrino experiments, intense electron-capture sources were fabricated to measure the responses of the radiochemical SAGE and GALLEX/GNO detectors to known fluxes of low-energy neutrinos. Such tests were viewed at the time as a cross-check, given the many tests of $^{71}$Ge recovery and counting that had been routinely performed, with excellent results. However, the four $^{51}$Cr and $^{37}$Ar source experiments yielded rates below expectations, a result commonly known as the Ga anomaly. As the intensity of the electron-capture sources can be measured to high precision, the neutrino lines they produce are fixed by known atomic and nuclear rates, and the neutrino absorption cross section on $^{71}$Ga is tightly constrained by the lifetime of $^{71}$Ge, no simple explanation for the anomaly has been found. To check these calibration experiments, a dedicated experiment BEST was performed, utilizing a neutrino source of unprecedented intensity and a detector optimized to increase statistics while providing some information on counting rate as a function of distance from the source. The results BEST obtained are consistent with the earlier solar neutrino calibration experiments, and when combined with those measurements, yield a Ga anomaly with a significance of approximately $4\sigma$, under conservative assumptions. But BEST found no evidence of distance dependence and thus no explicit indication of new physics. In this review we describe the extensive campaigns carried out by SAGE, GALLEX/GNO, and BEST to demonstrate the reliability and precision of their experimental procedures, including $^{71}$Ge recovery, counting, and analysis. We also describe efforts to define uncertainties in the neutrino capture cross section. With the results from BEST, an anomaly remains.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. A possible solution to the gallium anomaly moving beyond the leptonic wave function factorization

    hep-ph 2025-12 conditional novelty 6.0 of 10

    A non-factorized amplitude treatment with a fitted sign-changing nuclear transition density reduces the predicted νe-71Ga capture rate by ~20%, absorbing the gallium anomaly without new physics.

  2. The Gallium Solar Neutrino Capture Cross Section Revisited

    nucl-ex 2025-01 conditional novelty 6.0 of 10

    Updated 71Ga solar neutrino capture cross sections raise the 8B and hep rates by about 7% and 10% over Bahcall's 1997 values and cut the uncertainties by a factor of 2 to 3.

Pith tools