Pith. sign in

REVIEW 1 cited by

Electron Spectroscopy using Transition-Edge Sensors

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2403.01160 v1 pith:O6GKCX4U submitted 2024-03-02 physics.ins-det physics.app-ph

classification physics.ins-detphysics.app-ph
keywords electronenergyexperimentssensorsspectroscopytransition-edgeelectronsexisting
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Transition-edge sensors (TESs) have the potential to perform electron spectroscopic measurements with far greater measurement rates and efficiencies than can be achieved using existing electron spectrometers. Existing spectrometers filter electrons by energy before detecting a narrow energy band at a time, discarding the vast majority of electrons available for measurement. In contrast, transition-edge sensors (TES) have intrinsic energy sensitivity and so do not require prior filtering to perform energy-resolved measurements. Despite this fundamental advantage, TES electron spectroscopy has not, to our knowledge, previously been reported in the literature. We present the results of a set of proof-of-principle experiments demonstrating TES electron spectroscopy experiments using Mo/Au TESs repurposed for electron calorimetry. Using these detectors, we successfully measured the electron spectrum generated by an electron beam striking a graphite target with energies between 750 and 2000 eV, at a noise-limited energy resolution of 4 eV. Based on the findings of these experiments, we suggest improvements that could be made to TES design to enhance their electron detection capabilities through the use of of a dedicated electron absorber in the device with integrated electron optics.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Demonstration of a cryogenic, switchable electron source for low-temperature detector calibration

    physics.ins-det 2026-07 conditional novelty 6.0 of 10

    A cryogenic, switchable photoelectric electron source made from LED and aluminum foil was demonstrated and detected at 100–300 eV with TES microcalorimeters.

Pith tools