Pith. sign in

REVIEW 1 cited by

A CT Image Denoising Method with Residual Encoder-Decoder Network

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2404.01553 v1 pith:X2DQVYMQ submitted 2024-04-02 eess.IV

classification eess.IV
keywords imagenoisenetworkprocessingreductionapproachclinicalcomplexity
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Utilizing a low-dose CT approach significantly reduces the radiation exposure for patients, yet it introduces challenges, such as increased noise and artifacts in the resultant images, which can hinder accurate medical diagnostics. Traditional methods for noise reduction struggle with preserving image textures due to the complexity of modeling statistical properties directly within the image domain. To address these limitations, this study introduces an enhanced noise-reduction technique centered around an advanced residual encoder-decoder network. By incorporating recursive processing into the foundational network, this method reduces computational complexity and enhances the effectiveness of noise reduction. Furthermore, the introduction of a root-mean-square error and perceptual loss functions aims to retain the integrity of the images' textural details. The enhanced technique also includes optimized tissue segmentation, improving artifact management post-improvement. Validation using the TCGA-COAD clinical dataset demonstrates superior performance in both noise reduction and image quality, as measured by post-denoising PSNR and SSIM, compared to the existing WGAN approach. This advancement in CT image processing offers a practical solution for clinical applications, achieving lower computational demands and faster processing times without compromising image quality.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. TransGUNet: Transformer Meets Graph-based Skip Connection for Medical Image Segmentation

    cs.CV 2025-02 conditional novelty 6.0 of 10

    A graph-based skip connection with entropy-filtered spatial attention improves average medical-image segmentation accuracy and efficiency across 14 datasets.

Pith tools