Pith. sign in

REVIEW 1 cited by

Bayesian Windkessel calibration using optimized 0D surrogate models

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2404.14187 v2 pith:M7MCB6QC submitted 2024-04-22 cs.CE

classification cs.CE
keywords modelsposteriorwindkesselcalibrationmodelbayesianoptimizedapproximation
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Boundary condition (BC) calibration to assimilate clinical measurements is an essential step in any subject-specific simulation of cardiovascular fluid dynamics. Bayesian calibration approaches have successfully quantified the uncertainties inherent in identified parameters. Yet, routinely estimating the posterior distribution for all BC parameters in 3D simulations has been unattainable due to the infeasible computational demand. We propose an efficient method to identify Windkessel parameter posteriors using results from a single high-fidelity three-dimensional (3D) model evaluation. We only evaluate the 3D model once for an initial choice of BCs and use the result to create a highly accurate zero-dimensional (0D) surrogate. We then perform Sequential Monte Carlo (SMC) using the optimized 0D model to derive the high-dimensional Windkessel BC posterior distribution. We validate this approach in a publicly available dataset of N=72 subject-specific vascular models. We found that optimizing 0D models to match 3D data a priori lowered their median approximation error by nearly one order of magnitude. In a subset of models, we confirm that the optimized 0D models still generalize to a wide range of BCs. Finally, we present the high-dimensional Windkessel parameter posterior for different measured signal-to-noise ratios in a vascular model using SMC. We further validate that the 0D-derived posterior is a good approximation of the 3D posterior. The minimal computational demand of our method using a single 3D simulation, combined with the open-source nature of all software and data used in this work, will increase access and efficiency of Bayesian Windkessel calibration in cardiovascular fluid dynamics simulations.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Accelerated Patient-Specific Calibration via Differentiable Hemodynamics Simulations

    physics.med-ph 2024-12 conditional novelty 4.0 of 10

    A differentiable 1D hemodynamics solver in JAX enables gradient-based inference of Windkessel parameters from pressure waveforms.

Pith tools