Pith. sign in

REVIEW 2 cited by

Dose-aware Diffusion Model for 3D PET Image Denoising: Multi-institutional Validation with Reader Study and Real Low-dose Data

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2405.12996 v3 pith:K23Z7OVZ submitted 2024-05-02 eess.IV

classification eess.IV
keywords low-doseimagedifferentdiffusionimagingmodelimagesmodels
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Reducing scan times, radiation dose, and enhancing image quality for lower-performance scanners, are critical in low-dose PET imaging. Deep learning techniques have been investigated for PET image denoising. However, existing models have often resulted in compromised image quality when achieving low-count/low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, and patient populations. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we evaluated the proposed model using a total of 9,783 18F-FDG studies with low-dose levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by board-certified nuclear medicine physicians, experienced readers judged the images to be similar or superior to the full-dose images and previous DL baselines based on qualitative visual impression. Lesion-level quantitative accuracy was evaluated using a Monte Carlo simulation study and a lesion segmentation network. The presented results show the potential to achieve low-dose PET while maintaining image quality. Real low-dose scans was also included for evaluation.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. TauGenNet: Plasma-Driven Tau PET Image Synthesis via Text-Guided 3D Diffusion Models

    cs.CV 2025-09 conditional novelty 5.0 of 10

    A text-guided 3D diffusion model generates synthetic tau PET images from MRI anatomy and plasma p-tau217 levels, reproducing Alzheimer's tau progression patterns.

  2. Double-Constraint Diffusion Model with Nuclear Regularization for Ultra-low-dose PET Reconstruction

    cs.CV 2025-08 conditional novelty 5.0 of 10

    A frozen diffusion PET model outfitted with a low-rank nuclear transformer and dose-specific encoding controllers reconstructs ultra-low-dose images and selects the right controller when the dose is unknown.

Pith tools