Pith. sign in

REVIEW 2 cited by

Exploring pulsar timing precision: A comparative study of polarization calibration methods for NANOGrav data from the Green Bank Telescope

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2406.13463 v2 pith:KTDTDO7O submitted 2024-06-19 astro-ph.HE astro-ph.IM

classification astro-ph.HEastro-ph.IM
keywords calibrationpulsartimingmethodspolarizationprecisionthreeobserved
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

Pulsar timing array experiments have recently uncovered evidence for a nanohertz gravitational wave background by precisely timing an ensemble of millisecond pulsars. The next significant milestones for these experiments include characterizing the detected background with greater precision, identifying its source(s), and detecting continuous gravitational waves from individual supermassive black hole binaries. To achieve these objectives, generating accurate and precise times of arrival of pulses from pulsar observations is crucial. Incorrect polarization calibration of the observed pulsar profiles may introduce errors in the measured times of arrival. Further, previous studies (e.g., van Straten 2013; Manchester et al. 2013) have demonstrated that robust polarization calibration of pulsar profiles can reduce noise in the pulsar timing data and improve timing solutions. In this paper, we investigate and compare the impact of different polarization calibration methods on pulsar timing precision using three distinct calibration techniques: the Ideal Feed Assumption (IFA), Measurement Equation Modeling (MEM), and Measurement Equation Template Matching (METM). Three NANOGrav pulsars-PSRs J1643$-$1224, J1744$-$1134, and J1909$-$3744-observed with the 800 MHz and 1.5 GHz receivers at the Green Bank Telescope (GBT) are utilized for our analysis. Our findings reveal that all three calibration methods enhance timing precision compared to scenarios where no polarization calibration is performed. Additionally, among the three calibration methods, the IFA approach generally provides the best results for timing analysis of pulsars observed with the GBT receiver system. We attribute the comparatively poorer performance of the MEM and METM methods to potential instabilities in the reference noise diode coupled to the receiver and temporal variations in the profile of the reference pulsar, respectively.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Searches for signatures of ultra-light axion dark matter in polarimetry data of the European Pulsar Timing Array

    astro-ph.CO 2024-12 conditional novelty 6.0 of 10

    Analysis of EPTA pulsar polarimetry finds no evidence for ultra-light axion dark matter, sets upper limits on the axion-photon coupling, and attributes a common 2-year-period signal to ionospheric Faraday rotation.

  2. Pulse Profile Variability of PSR J1022+1001 in NANOGrav Data

    astro-ph.HE 2024-12 conditional novelty 5.0 of 10

    PSR J1022+1001's pulse profile variability survives rigorous MEM and METM polarization calibration and is consistent across frequency, favoring an intrinsic pulsar origin.

Pith tools