Pith. sign in

REVIEW 1 cited by

Calibration of the NEXT-White detector using ^(83m)Kr decays

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1804.01780 v5 pith:ALKU2OU2 submitted 2018-04-05 physics.ins-det hep-ex

Calibration of the NEXT-White detector using ^(83m)Kr decays

classification physics.ins-det hep-ex
keywords fwhmstatbetaenergynext-whitecalibrationcalibrationschamber
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterr\'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 $\pm$ 0.010 (stat.) $\pm$ 0.324 (sys.)) % FWHM in the full chamber and (3.804 $\pm$ 0.013 (stat.) $\pm$ 0.112 (sys.)) % FWHM in a restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values translate into resolutions of (0.516 $\pm$ 0.0014 (stat.) $\pm$ 0.0421 (sys.)) % FWHM and (0.4943 $\pm$ 0.0017 (stat.) $\pm$ 0.0146 (sys.)) % FWHM at the $Q_{\beta\beta}$ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Detection of scintillation light in noble gases with wavelength-shifting optical fibers

    physics.ins-det 2026-07 accept novelty 5.0

    TPB-coated WLS fibers achieve LCE of 1.18% (Xe) and 1.07% (Ar) up to 8.5 bar with SiPM readout, confirmed by an independent PMT setup after PDE scaling.