Pith. sign in

REVIEW

Technical note: On the use of polychromatic cameras for high spatial resolution spectral dose measurements

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2112.00077 v1 pith:NOKACGTO submitted 2021-11-30 physics.med-ph

classification physics.med-ph
keywords measurementsalgorithmsscintillationdemosaicingimagespolychromaticbilinearcamera
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Despite the demonstrated benefits of hyperspectral formalism for stem effect corrections in the context of fiber dose measurements, this approach has not been yet translated into volumetric measurements where cameras are typically used for their distinguishing spatial resolution. This work investigates demosaicing algorithms for polychromatic cameras based spectral imaging. The scintillation and Cherenkov signals produced in a radioluminescent phantom are imaged by a polychromatic camera and isolated using the spectral formalism. To do so, five demosaicing algorithms are investigated from calibration to measurements: a clustering method and four interpolation algorithms. The resulting accuracy of scintillation and Cherenkov images is evaluated with measurements of the differences (mean $\pm$ standard deviation) between the obtained and expected signals from profiles drawn across a scintillation spot. Signal-to-noise ratio and signal-to-background ratio are further measured and compared in the resulting scintillation images. Clustering, OpenCV, bilinear, Malvar and Menon demosaicing algorithms respectively yielded differences of $3\pm6\%$, $0.1\pm0.5\%$, $0.5\pm0.5\%$, $1\pm3\%$ and $1\pm4\%$ in the resulting scintillation images. For the Cherenkov images, all algorithms provided differences below 1\%. All methods enabled measurements over the detectability (SBR>2) and sensitivity (SNR>5) thresholds with the bilinear algorithm providing the best SNR value. Hence, radioluminescent signals can accurately be isolated using a single polychromatic camera. Moreover, demosaicing using a bilinear kernel provided the best results and enabled stem effect subtraction while preserving the full spatial resolution of the camera.

Discussion (0). Continue with ORCID to comment.

Pith tools