Pith. sign in

REVIEW 1 cited by

The Superconducting TESLA Cavities

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv physics/0003011 v1 pith:PTEPUAGU submitted 2000-03-04 physics.acc-ph

The Superconducting TESLA Cavities

classification physics.acc-ph
keywords cavitiestesladesigngradienttestaveragecavityeacc
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The conceptional design of the proposed linear electron-positron collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with an accelerating gradient of Eacc >= 25 MV/m at a quality factor Q0 > 5E+9. The design goal for the cavities of the TESLA Test Facility (TTF) linac was set to the more moderate value of Eacc >= 15 MV/m. In a first series of 27 industrially produced TTF cavities the average gradient at Q0 = 5E+9 was measured to be 20.1 +- 6.2 MV/m, excluding a few cavities suffering from serious fabrication or material defects. In the second production of 24 TTF cavities additional quality control measures were introduced, in particular an eddy-current scan to eliminate niobium sheets with foreign material inclusions and stringent prescriptions for carrying out the electron-beam welds. The average gradient of these cavities at Q0 = 5E+9 amounts to 25.0 +- 3.2 MV/m with the exception of one cavity suffering from a weld defect. Hence only a moderate improvement in production and preparation techniques will be needed to meet the ambitious TESLA goal with an adequate safety margin. In this paper we present a detailed description of the design, fabrication and preparation of the TESLA Test Facility cavities and their associated components and report on cavity performance in test cryostats and with electron beam in the TTF linac. The ongoing R&D towards higher gradients is briefly addressed.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Cavity Multimodes as an Array for High-Frequency Gravitational Waves

    hep-ph 2026-01 conditional novelty 6.0

    A 9-cell microwave cavity's 18 modes can act as a synthetic detector array that reconstructs the direction, polarization, and chirp of a high-frequency gravitational-wave signal.