Recognition: unknown
MHz Gravitational Wave Constraints with Decameter Michelson Interferometers
read the original abstract
A new detector, the Fermilab Holometer, consists of separate yet identical 39-meter Michelson interferometers. Strain sensitivity achieved is better than $10^{-21} /{\sqrt{\rm{Hz}}}$ between 1 to 13 MHz from a 130-hr dataset. This measurement exceeds the sensitivity and frequency range made from previous high frequency gravitational wave experiments by many orders of magnitude. Constraints are placed on a stochastic background at 382 Hz resolution. The 3$\sigma$ upper limit on $\Omega_{\rm{GW}}$, the gravitational wave energy density normalized to the closure density, ranges from $5.6 \times 10^{12}$ at 1 MHz to $8.4 \times 10^{15}$ at 13 MHz. Another result from the same dataset is a search for nearby primordial black hole binaries (PBHB). There are no detectable monochromatic PBHBs in the mass range $0.83$ - $3.5 \times 10^{21}$g between the earth and the moon. Projections for a chirp search with the same dataset increases the mass range to $0.59 - 2.5 \times 10^{25}$g and distances out to Jupiter. This result presents a new method for placing limits on a poorly constrained mass range of primordial black holes. Additionally, solar system searches for PBHBs place limits on their contribution to the total dark matter fraction.
This paper has not been read by Pith yet.
Forward citations
Cited by 1 Pith paper
-
Super-Heisenberg protocol for dark matter and high-frequency gravitational wave search
A protocol using squeezed states in 2D ion crystals in a Penning trap achieves super-Heisenberg sensitivity for axion-like particles, dark photons, and high-frequency gravitational waves while accounting for decoherence.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.