Pith. sign in

REVIEW 3 cited by

Force and acceleration sensing with optically levitated nanogram masses at microkelvin temperatures

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2001.10931 v1 pith:QMB3GQ3Y submitted 2020-01-29 physics.optics physics.ins-detquant-ph

classification physics.opticsphysics.ins-detquant-ph
keywords accelerationcoolingforcelevitatedopticallysensitivitybettermasses
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

This paper demonstrates cooling of the center-of-mass motion of 10 $\mu$m-diameter optically levitated silica spheres to an effective temperature of $50\pm22 \mu$K, achieved by minimizing the technical pointing noise of the trapping laser. This low noise leads to an acceleration and force sensitivity of $95\pm41$ n$g/\sqrt{\mathrm{Hz}}$ ($g = 9.8$ m/s$^2$) and $0.95\pm0.11$ aN$/\sqrt{\mathrm{Hz}}$, respectively, at frequencies near 50 Hz. This force sensitivity is comparable to that demonstrated for optically levitated nanospheres that are $10^4$ times less massive, corresponding to an acceleration sensitivity that is several orders of magnitude better. It is further shown that under these conditions the spheres remain stably trapped at pressures of $\sim 10^{-7}$ mbar with no active cooling for periods longer than a day. Feedback cooling is still necessary in the moderate-pressure regime, motivating a comprehensive study of the loss mechanisms of the microspheres and providing better understanding of the requirements for feedback-free optical trapping in vacuum. This work can enable high-sensitivity searches for accelerations and forces acting on micron-sized masses, including those that could be produced by new physics beyond the Standard Model.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. A compact beta particle momentum detector

    physics.ins-det 2026-08 conditional novelty 6.0 of 10

    A new UHV-compatible beta detector combining two CMOS tracking planes with a scintillator-SiPM calorimeter reports 35% efficiency above 500 keV, 5% energy resolution at 1 MeV, and sub-mm vertexing for the QuIPS levita...

  2. Searching for Ultralight Dark Matter with MOLeQuTE: a Massive Optically Levitated Quantum Tabletop Experiment

    hep-ph 2025-11 conditional novelty 6.0 of 10

    A proposed optically levitated milligram-scale plate sensor could reach the standard quantum limit and probe new parameter space for ultralight B-L vector dark matter.

  3. Impulse measurements enhanced with squeezed readout light

    quant-ph 2025-02 accept novelty 6.0 of 10

    Frequency-dependent squeezed readout lowers the impulse detection threshold as e^{-r}, down to a damping-limited floor of Δp_SQL/√Q; losses soften the gain to e^{-r/2}.

Pith tools