Pith. sign in

REVIEW 2 cited by

A Compact Optical Six-Axis Force/Torque Sensor for Legged Robots Using a Polymorphic Calibration Method

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2309.04720 v2 pith:LORGENMW submitted 2023-09-09 cs.RO physics.ins-det

classification cs.ROphysics.ins-det
keywords calibrationsensorsensingelementsforcemethodscompactcompared
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

This paper presents a novel design for a compact, lightweight 6-axis force/torque sensor intended for use in legged robots. The design promotes easy manufacturing and cost reduction, while introducing innovative calibration methods that simplify the calibration process and minimize effort. The sensor's advantages are achieved by streamlining the structure for durability, implementing noncontact sensors, and providing a wider sensing range compared to commercial sensors. To maintain a simple structure, the paper proposes a force sensing scheme using photocouplers where the sensing elements are aligned in-plane. This strategy enables all sensing elements to be fabricated on a single printed circuit board, eliminating manual labor tasks such as bonding and coating the sensing elements. The prototype sensor contains only four parts, costs less than $250, and exhibits high response frequency and performance. Traditional calibration methods present challenges, such as the need for specialized equipment and extensive labor. To facilitate easy calibration without the need for specialized equipment, a new method using optimal control is proposed. To verify the feasibility of these ideas, a prototype six-axis F/T sensor was manufactured. Its performance was evaluated and compared to a reference F/T sensor and previous calibration methods.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. A Miniature High-Resolution Tension Sensor Based on a Photo-Reflector for Robotic Hands and Grippers

    cs.RO 2025-07 conditional novelty 5.0 of 10

    A photo-reflector-based miniature tension sensor with a symmetric elastomer and flexure hinges achieves ~9.9 mN resolution and 0.455 N RMSE, but the 200 N full-scale claims rest on calibration data limited to 70 N.

  2. Parameter Optimization of Optical Six-Axis Force/Torque Sensor for Legged Robots

    cs.RO 2025-02 conditional novelty 4.0 of 10

    An optical six-axis force/torque sensor with optimized T-beam geometry survives quadruped impacts with 0.375% drift, versus 3.93% for a commercial sensor.

Pith tools