Pith. sign in

REVIEW 3 cited by

Calibrating VLBI Polarization Data Using GPCAL. II. Time-Dependent Calibration

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2310.03244 v1 pith:K2L6K3YS submitted 2023-10-05 astro-ph.IM

Calibrating VLBI Polarization Data Using GPCAL. II. Time-Dependent Calibration

classification astro-ph.IM
keywords methodpolarizationdataleakagesoff-axisvlbiamplitudesbeen
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

We present a new method of time-dependent instrumental polarization calibration for Very Long Baseline Interferometry (VLBI). This method has been implemented in the recently developed polarization calibration pipeline GPCAL. Instrumental polarization, also known as polarimetric leakage, is a direction-dependent effect, and it is not constant across the beam of a telescope. Antenna pointing model accuracy is usually dependent on time, resulting in off-axis polarimetric leakages that can vary with time. The method is designed to correct for the off-axis leakages with large amplitudes that can severely degrade linear polarization images. Using synthetic data generated based on real Very Long Baseline Array (VLBA) data observed at 43 GHz, we evaluate the performance of the method. The method was able to reproduce the off-axis leakages assumed in the synthetic data, particularly those with large amplitudes. The method has been applied to two sets of real VLBA data and the derived off-axis leakages show very similar trends over time for pairs of nearby sources. Furthermore, the amplitudes of the off-axis leakages are strongly correlated with the antenna gain correction factors. The results demonstrate that the method is capable of correcting for the off-axis leakages present in VLBI data. By calibrating time-dependent instrumental polarization, the rms-noise levels of the updated linear polarization images have been significantly reduced. The method is expected to substantially enhance the quality of linear polarization images obtained from existing and future VLBI observations.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. VAPOLA -- A multi-year, multi-band polarization survey of AGN and Sgr A* at mm wavelengths with ALMA I. Survey Overview and Science-Ready Archival Products

    astro-ph.GA 2026-07 accept novelty 6.0

    An automated pipeline and web portal deliver science-ready, full-polarization ALMA data products from VLBI campaigns for AGN and Sgr A* across Bands 3, 6, and 7.

  2. VAPOLA -- A multi-year, multi-band polarization survey of AGN and Sgr A* at mm wavelengths with ALMA I. Survey Overview and Science-Ready Archival Products

    astro-ph.GA 2026-07 conditional novelty 6.0

    VAPOLA releases multi-epoch multi-band ALMA full-Stokes products and polarimetric fits for AGN and Sgr A* via an automated pipeline and web portal.

  3. Dynamics and geometry of the inner sub-parsec-scale jet in 3C 279 observed with the Event Horizon Telescope

    astro-ph.GA 2026-07 conditional novelty 5.0

    EHT 2021 images of 3C 279 reveal an intrinsic, sideways-elongated jet base whose components move at apparent speeds up to 10c, implying a sub-parsec bend toward the observer and viewing angles below one degree.