REVIEW 2 cited by
The abundance discrepancy in ionized nebulae: which are the correct abundances?
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
The abundance discrepancy in ionized nebulae: which are the correct abundances?
read the original abstract
Ionized nebulae are key to understanding the chemical composition and evolution of the Universe. Among these nebulae, H~{\sc ii} regions and planetary nebulae are particularly important as they provide insights into the present and past chemical composition of the interstellar medium, along with the nucleosynthetic processes involved in the chemical evolution of the gas. However, the heavy-element abundances derived from collisional excited lines (CELs) and recombination lines (RLs) do not align. This longstanding abundance-discrepancy problem calls into question our absolute abundance determinations. Which of the lines (if any) provides the correct heavy-element abundances? Recently, it has been shown that there are temperature inhomogeneities concentrated within the highly ionized gas of the H~{\sc ii} regions, causing the reported discrepancy. However, planetary nebulae do not exhibit the same trends as the H~{\sc ii} regions, suggesting a different origin for the abundance discrepancy. In this proceedings, we briefly discuss the state-of-the-art of the abundance discrepancy problem in both H~{\sc ii} regions and planetary nebulae.
Forward citations
Cited by 2 Pith papers
-
Exploring the synergies of $[\mathrm{O\,II}]\lambda 3727$ with MUSE spectroscopy in PHANGS H II regions
Adding SITELLE [O II] to PHANGS-MUSE for 556 H II regions recovers known metallicity-calibration offsets, shows <0.03–0.04 dex gradient scatter for many methods, and favors [S III]/[S II] as a robust ionization tracer.
-
Exploring the synergies of $[\mathrm{O\,II}]\lambda 3727$ with MUSE spectroscopy in PHANGS H II regions
Combining [O II] doublet data with MUSE spectra creates a homogeneous H II region catalog and compares strong-line metallicity calibrations, showing low scatter in radial gradients and [S III]/[S II] as a robust ioniz...
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.