Pith. sign in

REVIEW 2 minor 1 cited by

In-flight calibration of the Wide-field X-ray Telescope on board the Einstein Probe

T0 review · 0 major / 2 minor · reviewed 2026-06-29 · grok-4.3

Pith's one-line read In-orbit calibration shows the Wide-field X-ray Telescope matches its ground performance across key metrics.

desk verdict This paper gives the first published in-orbit numbers for the WXT on Einstein Probe, showing performance close to ground tests with median 4.3 arcmin resolution and some low-energy degradation in a few modules. read the letter →

arxiv 2606.28101 v1 pith:3EGRF46G submitted 2026-06-26 astro-ph.IM astro-ph.HEhep-exphysics.ins-det

classification astro-ph.IMastro-ph.HEhep-exphysics.ins-det
keywords Wide-fieldX-rayTelescopein-flightcalibrationlobster-eyeopticsspatialresolutioneffectiveareadetectorstabilityEinsteinProbe
verification ladder T0 review T1 audit T2 compute T3 formal

The pith

A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.

The reading

The paper presents results from the first two and a half years of operations for the Wide-field X-ray Telescope on the Einstein Probe. Using observations of standard sources such as the Crab Nebula, Scorpius X-1, and Cassiopeia A, the authors measure spatial resolution, source positioning accuracy, and effective area. These quantities align with pre-launch ground calibrations, with a median resolution of about 4.3 arcminutes and positioning accuracy of 1.3 arcminutes at 90 percent . The effective area shows consistency within roughly 10 percent systematic uncertainty in the 0.5 to 4 keV range, while most detectors remain stable. The results are incorporated into the calibration database to support scientific data analysis.

What carries the argument

Systematic observations of standard celestial sources to quantify focal-spot full width at half maximum, positioning offsets, and effective area across detector modules.

What would settle it

A measured effective area or median full width at half maximum that deviates from ground predictions by more than the reported 10 percent uncertainty across multiple modules would falsify the agreement claim.

Watch

Extended reading notes

Core claim

The in-orbit performance of the WXT agrees with prelaunch ground calibrations well. The spatial resolution, denoted by the full width at half maximum of the focal spot, typically ranges from 3 to 6 arcminutes across about 90 percent of the field of view, with a median of about 4.3 arcminutes. The post-calibration source positioning accuracy achieves 1.3 arcminutes at the 90 percent confidence level. The in-orbit effective area is consistent with model predictions and ground measurements, exhibiting an overall systematic uncertainty of less than or equal to 10 percent at 90 percent in the 0.5-4 keV band.

Load-bearing premise

The spectral, flux, and spatial properties of the chosen standard celestial sources are known independently to sufficient precision and stability to serve as accurate references for the full field of view.

Editorial extensions

If this is right

  • Data from the telescope can be processed with the updated calibration database for reliable scientific results.
  • The instrument maintains the expected sensitivity for detecting and localizing transient X-ray events over most of its field of view.
  • Long-term monitoring of the few modules showing low-energy degradation can track further changes without affecting the majority of observations.

Reading between the lines

Editorial extensions of the paper, not claims the author makes directly.

  • Future wide-field X-ray instruments using similar optics may rely on the same source-based calibration approach to verify in-orbit behavior quickly after launch.
  • The observed stability in energy scale from Cassiopeia A observations suggests the detectors can support spectroscopy of variable sources over multi-year missions.
Share X Bluesky LinkedIn Reddit HN

Editorial analysis

A structured set of objections, weighed in public.

Desk editor's note, referee report, simulated authors' rebuttal, and a circularity audit.

Referee Report

0 major / 2 minor

Summary. The manuscript reports the in-flight calibration of the Wide-field X-ray Telescope (WXT) aboard the Einstein Probe, based on observations of the Crab Nebula, Sco X-1, and Cas A over the first 2.5 years of operations. It concludes that in-orbit performance matches pre-launch ground calibrations, with spatial resolution (FWHM) ranging from 3' to 6' across ~90% of the FoV (median ~4.3'), post-calibration source positioning accuracy of 1.3' (90% CL), and effective area consistent with models to ≲10% systematic uncertainty (90% CL) in the 0.5-4 keV band. A subset of modules shows long-term low-energy degradation (~30-40% in 0.4-0.6 keV), while energy scale and spectral resolution remain stable; all calibration products are incorporated into the WXT CALDB.

Significance. If the results hold, the work supplies a necessary end-to-end validation of an instrument whose large FoV and sensitivity are intended for time-domain X-ray astronomy. The quantitative agreement with independent ground calibrations, the explicit reporting of module-to-module variations, and the delivery of products to the public CALDB directly support reliable scientific use of the data. The reliance on multiple, independently characterized celestial standards across the field of view adds robustness to the claimed performance metrics.

minor comments (2)
  1. Abstract: the phrase 'typically ranges from 3' to 6'' would be clearer if accompanied by the fraction of the FoV or number of modules that satisfy the quoted bounds, rather than the ~90% figure alone.
  2. The manuscript states that spectral evaluations with Cas A confirm stability of the energy scale and resolution, but does not indicate the number of epochs or total exposure used for this check; adding this detail would allow readers to assess the statistical power of the stability claim.

Simulated Author's Rebuttal

0 responses · 0 unresolved

We thank the referee for their positive review and recommendation to accept the manuscript. The assessment correctly highlights the robustness of the calibration results derived from multiple celestial standards and the public delivery of the CALDB products.

Circularity Check

0 steps flagged · score 0.0 of 10

No significant circularity

full rationale

The paper reports direct in-orbit measurements of WXT performance (FWHM, positioning accuracy, effective area) by observing standard celestial sources (Crab Nebula, Sco X-1, Cas A) whose spectral, spatial, and flux properties are taken as independently known. These observations are compared to pre-launch ground calibrations without any equation or step that reduces a claimed prediction to a fitted parameter from the same dataset, without self-definitional loops, and without load-bearing self-citations that justify uniqueness or an ansatz. The central claims rest on external benchmarks rather than internal construction, so the derivation chain is self-contained.

Assumptions & free parameters 0 free parameters · 1 assumptions · 0 invented entities

The central claim rests on the established properties of three standard calibrators rather than new free parameters or postulated entities.

assumptions (1)
  • domain assumption The spectral, flux, and spatial properties of the Crab Nebula, Sco X-1, and Cas A are known independently to sufficient precision and stability to serve as accurate references for characterizing the full field of view, energy response, and long-term behavior of every detector module.
    These sources are invoked as the basis for all in-orbit measurements described in the abstract.

how reviews work

0 comments
Cite this review

Pith. "Pith review of In-flight calibration of the Wide-field X-ray Telescope on board the Einstein Probe." pith.science (2026). https://pith.science/paper/3EGRF46G

@misc{pith2026260628101,
  author       = {Pith},
  title        = {Pith review of: In-flight calibration of the Wide-field X-ray Telescope on board the Einstein Probe},
  year         = {2026},
  howpublished = {\url{https://pith.science/paper/3EGRF46G}},
  note         = {Machine review of arXiv:2606.28101}
}
abstract

By utilizing novel lobster-eye optics, the Wide-field X-ray Telescope (WXT) onboard the Einstein Probe (EP) satellite achieves an unprecedented combination of a large instantaneous field-of-view (FoV) and high sensitivity for monitoring the dynamic X-ray sky. In this paper, we present the in-orbit calibration results of the WXT during its first two and a half years of operations. By conducting observations of standard celestial sources--including the Crab Nebula, Scorpius X-1, and Cassiopeia A--we systematically characterized key instrumental properties. Our analysis demonstrates that the in-orbit performance of the WXT agrees with prelaunch ground calibrations well. The spatial resolution, denoted by the full width at half maximum (FWHM) of the focal spot, typically ranges from $3'$ to $6'$ across $\sim$90% of the FoV, with a median of $\sim 4.3'$. The post-calibration source positioning accuracy achieves $1.3'$ (at the 90% confidence level). The in-orbit effective area is consistent with model predictions and ground measurements, exhibiting an overall systematic uncertainty of $\lesssim 10\%$ (90% C.L.) in the 0.5-4 keV band. While the vast majority of the detectors remain highly stable, a noticeable long-term degradation at the low-energy end ($\sim30\%$-$40\%$, 0.4-0.6 keV) is observed in a few specific modules. Furthermore, spectral evaluations using Cas A confirm the stability of the energy scale and spectral resolution of the focal-plane Complementary Metal-Oxide Semiconductor (CMOS) detectors. All derived calibration products have been incorporated into the WXT calibration database (CALDB). These results comprehensively verify the instrumental capabilities of the WXT, providing a solid foundation for the reliable analysis of scientific observations.

Figures

Figures reproduced from arXiv: 2606.28101 by the authors.

Figure 1
Figure 1. (Left panel) Mosaic of observational images of the Crab nebula taken from 6 × 6 incident directions across the FoV of CMOS 1. (Right panel) Zoom-in image of the PSF sampled at the detector coordinates of [RAWX, RAWY] ≈ [2250, 1650]. The PSF is composed of a bright focal spot region and two orthogonal cruciform arms, as predicted by lobster-eye optics [PITH_FULL_IMAGE:figures/full_fig_p005_1.png] view at source ↗
Figure 2
Figure 2. In-orbit PSF FWHM measured across different CMOS detectors. The left panel shows the mean and standard deviation of the FWHM measured along the major axis. The right panel shows the measurements along the minor axis [PITH_FULL_IMAGE:figures/full_fig_p005_2.png] view at source ↗
Figure 3
Figure 3. Distributions of the three characteristic measurements of the PSF FWHM obtained from the Crab and Sco X-1 observations during the first stage of calibration. From left to right panels: the lengths of the major axis, minor axis, and the area-equivalent radius (see text for detailed definitions). The ground measurements obtained at the XIB test facility (NAOC/CAS) are overplotted for comparison. the PSF characteristic… view at source ↗
Figures from the paper (10 more)
Figure 4
Figure 4. Figure 4: Exemplary quiver map representing the positional deviations between the expected and measured PSF focal spot centroids, using Sco X-1 data observed with CMOS 9. Panel (a) illustrates the offsets prior to the in-orbit localization calibration, and panel (b) shows the re…
Figure 5
Figure 5. Figure 5: Offsets between the WXT positions and the NED coordinates for 164,525 valid detections from 4,370 sources, displayed as a two￾dimensional histogram. The two circles denoted by dashed black and green lines correspond to the 68th and 90th percentiles of 1.2 ′ and 1.9 ′ ,…
Figure 6
Figure 6. Figure 6: Histogram (in grey) of the normalized positional offset x after incorporating the best-fit systematic uncertainty of 0.61′ (which corre￾sponds to 1.3 ′ at the 90% C.L.; see text for details), plotted alongside the theoretical Rayleigh distribution (red curve). A total …
Figure 7
Figure 7. Figure 7: Systematic source positioning error (at the 90% C.L.) for each individual CMOS detector. The red dashed line indicates the represen￾tative overall systematic uncertainty of 1.3 ′ for the entire WXT instru￾ment. NASA/IPAC Extragalactic Database (NED)3 , utilizing the co…
Figure 8
Figure 8. Figure 8: Spectral analysis of three Crab observations conducted during the commissioning phase. The source was located at the detector po￾sition of [3567, 3524] for CMOS 18 (blue symbols), [551, 1954] for CMOS 30 (green symbols), and [1219, 1165] for CMOS 39 (pink sym￾bols). Th…
Figure 9
Figure 9. Figure 9: Crab spectral fitting parameters for 46 detectors (excluding CMOS 34 and CMOS 41) onboard the EP-WXT instrument. Panels (a)–(d) show the photon index, the column density, the normalization of the power-law model, and the observed flux within the 0.5–4 keV band, respect…
Figure 10
Figure 10. Figure 10: Crab spectra obtained on CMOS 14 (left panel) and CMOS 32 (right panel) during different calibration epochs: February 2024, January 2025, and November 2025. The source was located at the center of the detector in these observations. The lower-energy ends (0.4–1 keV) o…
Figure 11
Figure 11. Figure 11: Ratio of the 0.4–0.6 keV count rate across different calibration epochs. The red dots denote the ratio between the third epoch (data ob￾tained from November 2025 to February 2026) and the second epoch (data obtained from January to February 2025), and the gray squares…
Figure 13
Figure 13. Figure 13: Comparison between the stacked Cas A spectra from differ￾ent operational stages, utilizing observations from CMOS 15. The data represented by red dots were acquired during the commissioning phase, and those represented by blue dots were obtained during the third cali￾…
Figure 12
Figure 12. Figure 12: (Upper panel) Spectral analysis of Cas A using the data re￾trieved from CMOS 38 during the commissioning phase, with a total ex￾posure of 25.5 ks. The observed data are denoted by gray symbols. The underlying continuum, described by a power-law model, is signified by …

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Calibration database design for the wide-field X-ray telescope on board the Einstein Probe

    astro-ph.IM 2026-07 accept novelty 5.0 of 10

    The WXT CALDB is a HEASARC/OGIP-compliant database of per-CMOS calibration files — bias, gain, bad pixels, effective area, response matrices, PSF and vignetting — with in-orbit updates validated against the Crab and Cas A.

Reference graph

Works this paper leans on

66 extracted references · 12 canonical work pages · cited by 1 Pith paper

  1. [1]

    2006, in ESA Special Publication, V ol

    Abbey, T., Carpenter, J., Read, A., et al. 2006, in ESA Special Publication, V ol. 604, The X-ray Universe 2005, ed. A. Wilson, 943

  2. [2]

    Angel, J. R. P. 1979, ApJ, 233, 364

  3. [3]

    Arnaud, K. A. 1996, in Astronomical Society of the Pacific Conference Series, V ol. 101, Astronomical Data Analysis Software and Systems V , ed. G. H. Jacoby & J. Barnes, 17

  4. [4]

    D., Wells, A., Abbey, A

    Carpenter, J. D., Wells, A., Abbey, A. F., & Ambrosi, R. M. 2008, A&A, 483, 941

  5. [5]

    2024, Journal of Astronomical Telescopes, Instruments, and Systems, 10, 026001

    Chen, M., Ling, Z., Liu, M., et al. 2024, Journal of Astronomical Telescopes, Instruments, and Systems, 10, 026001

  6. [6]

    2020, in Society of Photo-Optical Instrumen- tation Engineers (SPIE) Conference Series, V ol

    Chen, Y ., Cui, W., Han, D., et al. 2020, in Society of Photo-Optical Instrumen- tation Engineers (SPIE) Conference Series, V ol. 11444, Society of Photo- Optical Instrumentation Engineers (SPIE) Conference Series, 114445B

  7. [7]

    2026, AIP Advances, 16, 015208

    Chen, Y ., Li, Z., Wang, C., et al. 2026, AIP Advances, 16, 015208

  8. [8]

    2024, Experimental Astronomy, 57, 10

    Cheng, H., Ling, Z., Zhang, C., et al. 2024, Experimental Astronomy, 57, 10

Show all 66 references
  1. [9]

    2026, A&A, 710, A208

    Cheng, H., Pan, H.-W., Liu, Y ., et al. 2026, A&A, 710, A208

  2. [10]

    Q., Zhao, Q

    Cheng, H. Q., Zhao, Q. C., Tao, L., et al. 2025b, ApJ, 991, L41 Coti Zelati, F., Marino, A., Wang, Y . L., et al. 2026, ApJ, 1003, 224

  3. [11]

    2026, arXiv e-prints, arXiv:2603.26213

    Dai, C.-Y ., Quirola-Vásquez, J., Wang, Y .-H., et al. 2026, arXiv e-prints, arXiv:2603.26213

  4. [12]

    & Moorhead, A

    Drolshagen, G. & Moorhead, A. V . 2019, in Meteoroids: Sources of Meteors on Earth and Beyond, ed. G. O. Ryabova, D. J. Asher, & M. D. Campbell-Brown, 255

  5. [13]

    Feigelson, E. D. & Babu, G. J. 2012, Modern Statistical Methods for Astronomy

  6. [14]

    W., Brunton, A

    Fraser, G. W., Brunton, A. N., Lees, J. E., Pearson, J. F., & Feller, W. B. 1993, Nuclear Instruments and Methods in Physics Research A, 324, 404

  7. [15]

    W., Lees, J

    Fraser, G. W., Lees, J. E., Pearson, J. F., Sims, M. R., & Roxburgh, K. 1992, in Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Se- ries, V ol. 1546, Multilayer and Grazing Incidence X-Ray/EUV Optics, ed. R. B. Hoover, 41–52

  8. [16]

    E., Bautz, M

    Grant, C. E., Bautz, M. W., Kissel, S. M., LaMarr, B., & Prigozhin, G. Y . 2005, in Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Se- ries, V ol. 5898, UV , X-Ray, and Gamma-Ray Space Instrumentation for As- tronomy XIV , ed. O. H. W. Siegmund, 201–211

  9. [17]

    E., Bautz, M

    Grant, C. E., Bautz, M. W., Plucinsky, P. P., & Ford, P. G. 2024, in Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series, V ol. 13093, Space Telescopes and Instrumentation 2024: Ultraviolet to Gamma Ray, ed. J.-W. A. den Herder, S. Nikzad, & K. Nakazawa...

  10. [18]

    2025, MNRAS, 542, 583

    Haberl, F., Xu, Y ., Maitra, C., et al. 2025, MNRAS, 542, 583

  11. [19]

    2013, X-ray CCDs, ed

    Holland, A. 2013, X-ray CCDs, ed. M. C. E. Huber, A. Pauluhn, J. L. Culhane, J. G. Timothy, K. Wilhelm, & A. Zehnder (New York, NY: Springer New York), 443–453

  12. [20]

    L., Zhao, Q

    Huang, G. L., Zhao, Q. C., Tao, L., et al. 2026, arXiv e-prints, arXiv:2606.10566

  13. [21]

    Jiang, S.-Q., Xu, D., van Hoof, A. P. C., et al. 2025, arXiv e-prints, arXiv:2503.04306

  14. [22]

    C., Li, D

    Jin, C. C., Li, D. Y ., Jiang, N., et al. 2025, arXiv e-prints, arXiv:2501.09580

  15. [23]

    G., Abbey, A., Altieri, B., et al

    Kirsch, M. G., Abbey, A., Altieri, B., et al. 2005, in UV , X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XIV , ed. O. H. W. Siegmund, V ol. 5898 (SPIE), 58980S

  16. [24]

    G., Briel, U

    Kirsch, M. G., Briel, U. G., Burrows, D., et al. 2005, in Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series, V ol. 5898, UV , X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XIV , ed. O. H. W. Siegmund, 22–33

  17. [25]

    2026, Science Bulletin, 71, 538

    Li, D., Zhang, W., Yang, J., et al. 2026, Science Bulletin, 71, 538

  18. [26]

    2024, Optics Communications, 569, 130821

    Li, L., Zhang, C., Wang, J., et al. 2024, Optics Communications, 569, 130821

  19. [27]

    2022, PASP, 134, 115002

    Li, L., Zhang, Y ., Ouyang, M., et al. 2022, PASP, 134, 115002

  20. [28]

    X., Zhu, Z

    Li, W. X., Zhu, Z. P., Zou, X. Z., et al. 2025a, arXiv e-prints, arXiv:2504.17034

  21. [29]

    X., Sun, X

    Ling, Z. X., Sun, X. J., Zhang, C., et al. 2023, Research in Astronomy and As- trophysics, 23, 095007

  22. [30]

    N., & Ni, Q

    Luo, B., Chen, X., Huang, J., Brandt, W. N., & Ni, Q. 2026, arXiv e-prints, arXiv:2606.09981

  23. [31]

    K., Forster, K., Grefenstette, B., Harrison, F

    Madsen, K. K., Forster, K., Grefenstette, B., Harrison, F. A., & Miyasaka, H. 2022, Journal of Astronomical Telescopes, Instruments, and Systems, 8, 034003

  24. [32]

    K., Harrison, F

    Madsen, K. K., Harrison, F. A., Markwardt, C. B., et al. 2015, ApJS, 220, 8

  25. [33]

    2025, ApJ, 980, 268

    Mao, X., Liu, H.-Y ., Wang, S., et al. 2025, ApJ, 980, 268

  26. [34]

    N., Coti Zelati, F., et al

    Marino, A., Yang, H. N., Coti Zelati, F., et al. 2025, ApJ, 980, L36

  27. [35]

    L., Tennant, A., Grant, C

    Marshall, H. L., Tennant, A., Grant, C. E., et al. 2004, in Society of Photo- Optical Instrumentation Engineers (SPIE) Conference Series, V ol. 5165, X- Ray and Gamma-Ray Instrumentation for Astronomy XIII, ed. K. A. Flana- gan & O. H. W. Siegmund, 497–508

  28. [36]

    2000, A&A, 361, 695

    Massaro, E., Cusumano, G., Litterio, M., & Mineo, T. 2000, A&A, 361, 695

  29. [37]

    2018, PASJ, 70, 21 O’Dell, S

    Nakajima, H., Maeda, Y ., Uchida, H., et al. 2018, PASJ, 70, 21 O’Dell, S. L., Aldcroft, T. L., Blackwell, W. C., et al. 2007, in Society of Photo- Optical Instrumentation Engineers (SPIE) Conference Series, V ol. 6686, UV , X-Ray, and Gamma-Ray Space Instrumentation for Astro...

  30. [38]

    P., Bogdan, A., & Marshall, H

    Plucinsky, P. P., Bogdan, A., & Marshall, H. L. 2022, in Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series, V ol. 12181, Space Tele- scopes and Instrumentation 2022: Ultraviolet to Gamma Ray, ed. J.-W. A. den

  31. [39]

    H., Angelini, L., & Harding, A

    Pravdo, S. H., Angelini, L., & Harding, A. K. 1997, ApJ, 491, 808 Article number, page 12 of 13 Huaqing Cheng et al.: In-flight calibration of the Wide-field X-ray Telescope on board theEinstein Probe

  32. [40]

    2023, in International Conference on Space Optics — ICSO 2022, ed

    Rukdee, S., Burwitz, V ., Hartner, G., et al. 2023, in International Conference on Space Optics — ICSO 2022, ed. K. Minoglou, N. Karafolas, & B. Cugny, V ol. 12777, International Society for Optics and Photonics (SPIE), 127773F

  33. [41]

    2023, in Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series, V ol

    Rukdee, S., Burwitz, V ., Hartner, G., et al. 2023, in Society of Photo-Optical Instrumentation Engineers (SPIE) Conference Series, V ol. 12679, Optics for EUV , X-Ray, and Gamma-Ray Astronomy XI, ed. S. L. O’Dell, J. A. Gaskin, G. Pareschi, & D. Spiga, 1267910

  34. [42]

    2025, arXiv e-prints, arXiv:2505.07665

    Shu, X., Yang, L., Yang, H., et al. 2025, arXiv e-prints, arXiv:2505.07665

  35. [43]

    P., Li, D., Hall, X

    Srinivasaragavan, G. P., Li, D., Hall, X. J., et al. 2025, arXiv e-prints, arXiv:2512.10239 Strüder, L., Aschenbach, B., Bräuninger, H., et al. 2001, A&A, 375, L5

  36. [44]

    X., Liu, L

    Sun, H., Li, W. X., Liu, L. D., et al. 2024, arXiv e-prints, arXiv:2410.02315

  37. [45]

    W., Yang, J., et al

    Sun, H., Wang, C. W., Yang, J., et al. 2025, National Science Review, 12, nwae401

  38. [46]

    & Seward, F

    Toor, A. & Seward, F. D. 1974, AJ, 79, 995

  39. [47]

    Verner, D. A. & Yakovlev, D. G. 1995, A&AS, 109, 125

  40. [48]

    E., et al

    Virtanen, P., Gommers, R., Oliphant, T. E., et al. 2020, Nature Methods, 17, 261

  41. [49]

    L., Coti Zelati, F., Parent, E., et al

    Wang, Y . L., Coti Zelati, F., Parent, E., et al. 2026, arXiv e-prints, arXiv:2601.11784

  42. [50]

    G., Schröder, A

    Watson, M. G., Schröder, A. C., Fyfe, D., et al. 2009, A&A, 493, 339

  43. [51]

    C., Guainazzi, M., Jahoda, K., et al

    Weisskopf, M. C., Guainazzi, M., Jahoda, K., et al. 2010, ApJ, 713, 912

  44. [52]

    W., Brunton, A

    Willingale, R., Fraser, G. W., Brunton, A. N., & Martin, A. P. 1998, Experimental Astronomy, 8, 281

  45. [53]

    F., Martindale, A., et al

    Willingale, R., Pearson, J. F., Martindale, A., et al. 2016, in Society of Photo- Optical Instrumentation Engineers (SPIE) Conference Series, V ol. 9905, Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray, ed. J.-W. A. den Herder, T. Takahashi, & M. Bautz, 99051Y

  46. [54]

    2000, ApJ, 542, 914

    Wilms, J., Allen, A., & McCray, R. 2000, ApJ, 542, 914

  47. [55]

    2022, PASP, 134, 035006

    Wu, Q., Jia, Z., Wang, W., et al. 2022, PASP, 134, 035006

  48. [56]

    N., Maitra, C., Vasilopoulos, G., et al

    Yang, H. N., Maitra, C., Vasilopoulos, G., et al. 2025, MNRAS, 536, 1357

  49. [57]

    2022, PASP, 134, 065002

    Yang, X., Zhang, C., Wang, W., et al. 2022, PASP, 134, 065002

  50. [58]

    I., Fang, Y ., Zhang, B.-B., et al

    Yin, Y .-H. I., Fang, Y ., Zhang, B.-B., et al. 2025, arXiv e-prints, arXiv:2506.00435

  51. [59]

    I., Zhang, B.-B., Yang, J., et al

    Yin, Y .-H. I., Zhang, B.-B., Yang, J., et al. 2024, ApJ, 975, L27

  52. [60]

    K., et al

    Yuan, W., Amati, L., Cannizzo, J. K., et al. 2016, Space Sci. Rev., 202, 235

  53. [61]

    2025, Science China Physics, Mechanics, and Astronomy, 68

    Yuan, W., Dai, L., Feng, H., et al. 2025, Science China Physics, Mechanics, and Astronomy, 68

  54. [62]

    2026, arXiv e-prints, arXiv:2606.10014

    Yuan, W., Huang, Q.-J., Zhu, J.-P., et al. 2026, arXiv e-prints, arXiv:2606.10014

  55. [63]

    2022, The Einstein Probe Mission, ed

    Yuan, W., Zhang, C., Chen, Y ., & Ling, Z. 2022, The Einstein Probe Mission, ed. C. Bambi & A. Santangelo (Singapore: Springer Nature Singapore), 1–30

  56. [64]

    2018, in Society of Photo-Optical Instrumen- tation Engineers (SPIE) Conference Series, V ol

    Yuan, W., Zhang, C., Ling, Z., et al. 2018, in Society of Photo-Optical Instrumen- tation Engineers (SPIE) Conference Series, V ol. 10699, Space Telescopes and Instrumentation 2018: Ultraviolet to Gamma Ray, ed. J.-W. A. den Herder, S. Nikzad, & K. Nakazawa, 1069925

  57. [65]

    X., Sun, X

    Zhang, C., Ling, Z. X., Sun, X. J., et al. 2022, ApJ, 941, L2

  58. [66]

    2025, Science China Physics, Mechanics, and Astronomy, 68, 219511 Article number, page 13 of 13

    Zhang, W., Yuan, W., Ling, Z., et al. 2025, Science China Physics, Mechanics, and Astronomy, 68, 219511 Article number, page 13 of 13

Pith tools

Reviewed June 29, 2026 · model on record in the stance chip above.