The reviewed record of science sign in
Pith

arxiv: 2003.09253 · v1 · pith:J7MSDQW7 · submitted 2020-03-19 · eess.SY · cs.SY

Root Locus for SISO Dead-Time Systems: A Continuation Based Approach

Reviewed by Pithpith:J7MSDQW7open to challenge →

classification eess.SY cs.SY
keywords locusrootmethodcharacteristiccontinuationdead-timerootssiso
0
0 comments X
read the original abstract

We present a numerical method to plot the root locus of Single-Input-Single-Output (SISO) dead-time systems with respect to the controller gain or the system delay. We compute the trajectories of characteristic roots of the closed-loop system on a prescribed complex right half-plane. We calculate the starting, branch and boundary crossing roots of root-locus branches inside the region. We compute the root locus of each characteristic root based on a predictor-corrector type continuation method. To avoid the high sensitivity of roots with respect to the locus parameter in the neighborhood of branch points, the continuation method relies on a natural parameterization of the root-locus trajectory in terms of a distance in the (characteristic root, locus parameter)-space. The method is numerically stable for high order SISO dead-time systems.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.