Pith. sign in

REVIEW 1 cited by

NuSTAR Reveals Extreme Absorption in z < 0.5 Type 2 Quasars

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1506.05120 v1 pith:7MIE42IE submitted 2015-06-16 astro-ph.HE astro-ph.GA

classification astro-ph.HEastro-ph.GA
keywords quasarsx-rayabsorptioncompton-thicknustartypecandidatechandra
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

The intrinsic column density (NH) distribution of quasars is poorly known. At the high obscuration end of the quasar population and for redshifts z<1, the X-ray spectra can only be reliably characterized using broad-band measurements which extend to energies above 10 keV. Using the hard X-ray observatory NuSTAR, along with archival Chandra and XMM-Newton data, we study the broad-band X-ray spectra of nine optically selected (from the SDSS), candidate Compton-thick (NH > 1.5e24 cm^-2) type 2 quasars (CTQSO2s); five new NuSTAR observations are reported herein, and four have been previously published. The candidate CTQSO2s lie at z<0.5, have observed [OIII] luminosities in the range 8.4 < log (L_[OIII]/L_solar) < 9.6, and show evidence for extreme, Compton-thick absorption when indirect absorption diagnostics are considered. Amongst the nine candidate CTQSO2s, five are detected by NuSTAR in the high energy (8-24 keV) band: two are weakly detected at the ~ 3 sigma confidence level and three are strongly detected with sufficient counts for spectral modeling (>~ 90 net source counts at 8-24 keV). For these NuSTAR-detected sources direct (i.e., X-ray spectral) constraints on the intrinsic AGN properties are feasible, and we measure column densities ~2.5-1600 times higher and intrinsic (unabsorbed) X-ray luminosities ~10-70 times higher than pre-NuSTAR constraints from Chandra and XMM-Newton. Assuming the NuSTAR-detected type 2 quasars are representative of other Compton-thick candidates, we make a correction to the NH distribution for optically selected type 2 quasars as measured by Chandra and XMM-Newton for 39 objects. With this approach, we predict a Compton-thick fraction of f_CT = 36^{+14}_{-12} %, although higher fractions (up to 76%) are possible if indirect absorption diagnostics are assumed to be reliable.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. XMM-Newton and Swift Unveil Another X-Ray Transient in NGC 4945, XMM J130514.64-493311.27

    astro-ph.HE 2026-07 accept novelty 5.0 of 10

    A previously undetected X-ray transient, XMM J130514.64-493311.27, was discovered in NGC 4945 with properties consistent with an X-ray binary caught in outburst.

Pith tools