pith. sign in

arxiv: 1710.02272 · v2 · pith:3HMMELSJnew · submitted 2017-10-06 · 🌌 astro-ph.HE · astro-ph.IM

Optimal Frequency Ranges for Sub-Microsecond Precision Pulsar Timing

classification 🌌 astro-ph.HE astro-ph.IM
keywords frequencyprecisionpulsartimingbandwidthtimearrivalcenter
0
0 comments X
read the original abstract

Precision pulsar timing requires optimization against measurement errors and astrophysical variance from the neutron stars themselves and the interstellar medium. We investigate optimization of arrival time precision as a function of radio frequency and bandwidth. We find that increases in bandwidth that reduce the contribution from receiver noise are countered by the strong chromatic dependence of interstellar effects and intrinsic pulse-profile evolution. The resulting optimal frequency range is therefore telescope and pulsar dependent. We demonstrate the results for five pulsars included in current pulsar timing arrays and determine that they are not optimally observed at current center frequencies. For those objects, we find that better choices of total bandwidth as well as center frequency can improve the arrival-time precision. Wideband receivers centered at somewhat higher frequencies with respect to the currently adopted receivers can reduce required overall integration times and provide significant improvements in arrival time uncertainty by a factor of ~sqrt(2) in most cases, assuming a fixed integration time. We also discuss how timing programs can be extended to pulsars with larger dispersion measures through the use of higher-frequency observations.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. The NANOGrav 15 yr Data Set: Customized Chromatic Noise Models

    astro-ph.HE 2026-06 unverdicted novelty 5.0

    Customized chromatic noise models for 67 pulsars detect non-dispersive delays in 21 cases, alter achromatic noise inferences in 19, and enable solar wind density estimates over 1.5 cycles.

  2. The NANOGrav 15 yr Data Set: Impacts of Customized Chromatic Noise Models on Gravitational Wave Analyses

    astro-ph.CO 2026-06 unverdicted novelty 4.0

    Customized chromatic noise models applied to NANOGrav 15 yr data raise the Bayes factor for Hellings-Downs GWB correlations by a factor of ~8, lower the amplitude to 2.1e-15, and increase the spectral index to 3.5.