Pith. sign in

REVIEW

CyTran: A Cycle-Consistent Transformer with Multi-Level Consistency for Non-Contrast to Contrast CT Translation

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2110.06400 v3 pith:CW6JRJUN submitted 2021-10-12 eess.IV cs.CVcs.LG

classification eess.IVcs.CVcs.LG
keywords contrastcytrannon-contrastnovelscansapproachcycle-consistencycycle-consistent
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

We propose a novel approach to translate unpaired contrast computed tomography (CT) scans to non-contrast CT scans and the other way around. Solving this task has two important applications: (i) to automatically generate contrast CT scans for patients for whom injecting contrast substance is not an option, and (ii) to enhance the alignment between contrast and non-contrast CT by reducing the differences induced by the contrast substance before registration. Our approach is based on cycle-consistent generative adversarial convolutional transformers, for short, CyTran. Our neural model can be trained on unpaired images, due to the integration of a multi-level cycle-consistency loss. Aside from the standard cycle-consistency loss applied at the image level, we propose to apply additional cycle-consistency losses between intermediate feature representations, which enforces the model to be cycle-consistent at multiple representations levels, leading to superior results. To deal with high-resolution images, we design a hybrid architecture based on convolutional and multi-head attention layers. In addition, we introduce a novel data set, Coltea-Lung-CT-100W, containing 100 3D triphasic lung CT scans (with a total of 37,290 images) collected from 100 female patients (there is one examination per patient). Each scan contains three phases (non-contrast, early portal venous, and late arterial), allowing us to perform experiments to compare our novel approach with state-of-the-art methods for image style transfer. Our empirical results show that CyTran outperforms all competing methods. Moreover, we show that CyTran can be employed as a preliminary step to improve a state-of-the-art medical image alignment method. We release our novel model and data set as open source at https://github.com/ristea/cycle-transformer.

Discussion (0). Continue with ORCID to comment.

Pith tools