Pith. sign in

REVIEW 2 cited by

Ultra-fast detection of the center frequency of a spectral line from amplitude-weighted average

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2303.12544 v2 pith:PG6J5AN6 submitted 2023-03-22 physics.atom-ph physics.app-phphysics.data-an

classification physics.atom-phphysics.app-phphysics.data-an
keywords methodfrequencycentrallineprocessingresonancespectralaccuracy
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Spectroscopy methods often require calculating the central frequency of a resonance line, that is usually implemented by finding a best fit to the spectrum by a line-shape function. Such an iterative procedure is slow and requires an initial guess. We report an analytical method for calculating the central frequency of a spectral line by using the mean value of its frequencies, which are weighted by corresponding normalized intensities. We use this method to calculate two-dimensional arrays of central frequencies from parallely measured magnetic resonance spectra, which are optically detected by a camera sensor in a thin layer of NV centers with superparamagnetic hemozoin crystals on top of it. We demonstrate that our analytical method is more than 800 times faster than the fitting procedure without significant loss of accuracy. For a 400x400 pixels sensing array, this method is almost instantaneous, while fitting with the Lorentz function requires several minutes of post-processing on a 4-core MacBook Pro. When a resonance is beyond the spectral range, the amplitude-weighted-mean method does not fail, but it alternates its center frequency proportionally to the mismatch distance. Our method will be useful for spectroscopic applications that require high performance of data processing, allowing their fast optimization, inline processing and real-time output of results. It can also be used for automatic analysis of single spectra, when accuracy of the frequency detection could be slightly (<10%) reduced for sake of stability and simplicity of the data processing.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Nitrogen-Vacancy Magnetometry of Edge Magnetism in WS2 Flakes

    cond-mat.mes-hall 2025-05 conditional novelty 6.0 of 10

    Wide-field NV magnetometry shows room-temperature magnetic stray fields localized at the edges of WS2 flakes, with an inferred edge magnetization tilted slightly out of the flake plane.

  2. Quantum diamond microscopy of individual vaterite microspheres containing magnetite nanoparticles

    physics.bio-ph 2025-04 conditional novelty 5.0 of 10

    Widefield quantum diamond microscopy maps stray fields of individual vaterite microspheres loaded with magnetite nanoparticles, showing a drop in signal between 10 nm and 20 nm particle sizes.

Pith tools