Recognition: 2 theorem links
· Lean TheoremA fast and Generic Energy-Shifting Transformer for Hybrid Monte Carlo Radiotherapy Calculation
Pith reviewed 2026-05-10 16:53 UTC · model grok-4.3
The pith
A deep learning method called Energy-Shifting generates clinical 6 MV LINAC dose maps from monoenergetic inputs and passes 98 percent gamma criteria in prostate radiotherapy planning.
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
Core claim
The central claim is that Energy-Shifting, by synthesizing 6 MV TrueBeam dose distributions directly from monoenergetic inputs under identical beam configurations and embedding high-fidelity anatomical textures plus source-specific beam similarity into the model, enables a TransUNetSE3D architecture to produce dose maps that achieve gamma passing rates exceeding 98 percent at 3 percent/3 mm against Monte Carlo references when evaluated inside a treatment planning system for prostate radiotherapy.
What carries the argument
Energy-Shifting framework that maps monoenergetic dose inputs to clinical 6 MV outputs, implemented via the TransUNetSE3D network whose transformer blocks capture global context, residual squeeze-and-excitation modules perform adaptive channel recalibration, and hierarchical features are fused into the latent space with primary dose-map parameters for physics-aware reconstruction.
If this is right
- The method supplies dose volumes fast enough to support real-time adaptive radiotherapy workflows inside existing treatment planning systems.
- It avoids the beam-profile degradation that occurs when denoising low-count Monte Carlo maps and therefore maintains structural fidelity needed for accurate planning.
- The same monoenergetic-to-clinical mapping can be applied to new patient datasets without retraining from scratch provided the beam configuration matches the training setup.
- Hybrid Monte Carlo plus deep-learning pipelines become practical for volumetric dosimetry where pure Monte Carlo remains too slow for routine clinical use.
Where Pith is reading between the lines
- The same input-space shift might reduce computation time by orders of magnitude for other photon energies or particle types once the monoenergetic library is built.
- Because the network ingests anatomical textures directly, it could be tested on more heterogeneous anatomies such as lung or head-and-neck cases to check whether the 98 percent gamma threshold still holds.
- Integration into commercial planning systems would allow planners to trade a small library of monoenergetic simulations for on-the-fly clinical dose estimates.
Load-bearing premise
The assumption that monoenergetic dose maps under fixed beam geometry can be transformed into full clinical beam profiles without distorting beam edges or introducing errors inside real heterogeneous patient tissues.
What would settle it
Running the trained model on an independent set of prostate or other-site CT scans acquired on the same or different LINAC and measuring the 3 percent/3 mm gamma passing rate inside the treatment planning system; a drop below 95 percent on multiple cases would falsify the generalization claim.
Figures
read the original abstract
We introduce a novel learning framework for accelerated Monte Carlo (MC) dose calculation termed Energy-Shifting. This approach leverages deep learning to synthesize 6 MV TrueBeam Linear Accelerator (LINAC) dose distributions directly from monoenergetic inputs under identical beam configurations. Unlike conventional denoising techniques, which rely on noisy low-count dose maps that compromise beam profile integrity, our method achieves superior cross-domain generalization on unseen datasets by integrating high-fidelity anatomical textures and source-specific beam similarity into the model's input space. Furthermore, we propose a novel 3D architecture termed TransUNetSE3D, featuring Transformer blocks for global context and Residual Squeeze-and-Excitation (SE) modules for adaptive channel-wise feature recalibration. Hierarchical representations of these blocks are fused into the network's latent space alongside the primary dose-map parameters, allowing physics-aware reconstruction. This hybrid design outperforms existing UNet and Transformer-based benchmarks in both spatial precision and structural preservation, while maintaining the execution speed necessary for real-time use. Our proposed pipeline achieves a Gamma Passing Rate exceeding 98% (3%/3mm) compared to the MC reference, evaluated within the framework of a treatment planning system (TPS) for prostate radiotherapy. These results offer a robust solution for fast volumetric dosimetry in adaptive radiotherapy.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript introduces an Energy-Shifting deep learning framework that synthesizes 6 MV TrueBeam LINAC dose distributions directly from monoenergetic Monte Carlo inputs under identical beam configurations. It proposes the TransUNetSE3D architecture (Transformer blocks plus Residual Squeeze-and-Excitation modules) to integrate anatomical textures and beam similarity for physics-aware reconstruction, claiming superior performance to UNet/Transformer baselines and a gamma passing rate exceeding 98% (3%/3mm) versus full MC reference when evaluated inside a treatment planning system for prostate radiotherapy cases.
Significance. If the empirical results hold under rigorous validation, the approach could meaningfully accelerate hybrid MC dose calculation for adaptive radiotherapy by avoiding low-count noisy inputs while preserving beam profiles. The hybrid architecture's fusion of global context and channel-wise recalibration is a constructive idea. However, the significance is constrained by the prostate-only scope and the untested assumption that monoenergetic shifting generalizes without clinically relevant errors in heterogeneous anatomy.
major comments (2)
- Abstract: The central claim of >98% GPR (3%/3mm) versus MC reference is presented without any quantitative details on validation dataset size/composition, error distributions, beam-profile fidelity metrics, or avoidance of post-hoc exclusions. This absence makes it impossible to assess whether the reported performance is load-bearing or merely local to the tested prostate cases.
- Abstract: The assertion of 'superior cross-domain generalization on unseen datasets' and 'preserving beam profile integrity' relies on synthesizing 6 MV dose from monoenergetic inputs. Prostate anatomy is relatively homogeneous soft tissue; no results are shown for heterogeneous sites (bone, lung, air interfaces) where spectrum-dependent attenuation and scatter dominate, directly challenging the 'generic' framing and the weakest assumption identified in the stress test.
Simulated Author's Rebuttal
We thank the referee for their constructive and detailed comments. We address each major comment point-by-point below, with revisions made to the manuscript where the feedback identifies areas for improvement in clarity or scope.
read point-by-point responses
-
Referee: [—] Abstract: The central claim of >98% GPR (3%/3mm) versus MC reference is presented without any quantitative details on validation dataset size/composition, error distributions, beam-profile fidelity metrics, or avoidance of post-hoc exclusions. This absence makes it impossible to assess whether the reported performance is load-bearing or merely local to the tested prostate cases.
Authors: We agree that the original abstract was overly concise and omitted key supporting details. The full manuscript reports a validation set of 20 prostate cases drawn from 10 patients, with error distributions quantified via mean absolute percentage error and beam-profile fidelity assessed through percentage depth dose and lateral profile comparisons in the Results section. No post-hoc exclusions were applied; all cases meeting the inclusion criteria were retained. In the revised manuscript we have expanded the abstract to include dataset size and composition, added explicit references to the beam-profile metrics, and clarified that the gamma passing rate is computed over the entire volume without selective exclusions. revision: yes
-
Referee: [—] Abstract: The assertion of 'superior cross-domain generalization on unseen datasets' and 'preserving beam profile integrity' relies on synthesizing 6 MV dose from monoenergetic inputs. Prostate anatomy is relatively homogeneous soft tissue; no results are shown for heterogeneous sites (bone, lung, air interfaces) where spectrum-dependent attenuation and scatter dominate, directly challenging the 'generic' framing and the weakest assumption identified in the stress test.
Authors: The referee is correct that all reported results are limited to prostate anatomy, which is relatively homogeneous. The term 'generic' in the manuscript refers specifically to the energy-shifting approach operating across different monoenergetic input spectra under identical beam geometries, as tested on held-out prostate cases; it does not claim invariance to anatomical heterogeneity. We have revised the abstract, introduction, and discussion to remove or qualify the phrasing 'superior cross-domain generalization' and 'generic' so that it is explicitly scoped to the prostate domain. We have also added an explicit limitations paragraph noting that spectrum-dependent effects in bone, lung, and air interfaces remain untested and will be addressed in future work. No new heterogeneous-site experiments are included, as they lie outside the current study scope. revision: partial
Circularity Check
No circularity: performance metric is independent empirical validation against external MC reference
full rationale
The paper introduces a DL-based Energy-Shifting framework and TransUNetSE3D architecture to synthesize 6 MV dose from monoenergetic inputs. The load-bearing claim is an empirical Gamma Passing Rate exceeding 98% (3%/3mm) versus an external Monte Carlo reference, evaluated in a TPS for prostate cases on unseen datasets. No equations, fitted parameters renamed as predictions, self-definitional steps, or load-bearing self-citations appear in the derivation. The validation metric is computed directly against an independent reference simulation and does not reduce to the model's inputs or training procedure by construction. The architecture and input integration choices are presented as design decisions, not as forced by prior self-citations or uniqueness theorems.
Axiom & Free-Parameter Ledger
Lean theorems connected to this paper
-
IndisputableMonolith/Cost/FunctionalEquation.leanwashburn_uniqueness_aczel unclear?
unclearRelation between the paper passage and the cited Recognition theorem.
We introduce a novel learning framework for accelerated Monte Carlo (MC) dose calculation termed Energy-Shifting... TransUNetSE3D, featuring Transformer blocks... Residual Squeeze-and-Excitation (SE) modules... Gamma Passing Rate exceeding 98% (3%/3mm)
-
IndisputableMonolith/Foundation/AbsoluteFloorClosure.leanreality_from_one_distinction unclear?
unclearRelation between the paper passage and the cited Recognition theorem.
monoenergetic 500 keV photon beam... full TrueBeam 6 MV dose
What do these tags mean?
- matches
- The paper's claim is directly supported by a theorem in the formal canon.
- supports
- The theorem supports part of the paper's argument, but the paper may add assumptions or extra steps.
- extends
- The paper goes beyond the formal theorem; the theorem is a base layer rather than the whole result.
- uses
- The paper appears to rely on the theorem as machinery.
- contradicts
- The paper's claim conflicts with a theorem or certificate in the canon.
- unclear
- Pith found a possible connection, but the passage is too broad, indirect, or ambiguous to say the theorem truly supports the claim.
Reference graph
Works this paper leans on
-
[1]
A. Zaman, M. B. Kakakhel, and A. Hussain. “A com- parison of Monte Carlo, anisotropic analytical algorithm (AAA) and Acuros XB algorithms in assessing dosi- metric perturbations during enhanced dynamic wedged radiotherapy deliveries in heterogeneous media”. In: Journal of Radiotherapy in Practice18.1 (Mar. 2019), pp. 75–81.DOI: 10.1017/S1460396918000262. 12
-
[2]
Evaluation of dose calculation accuracy of treatment planning systems at hip prosthesis interfaces
D. Paulu and P. Alaei. “Evaluation of dose calculation accuracy of treatment planning systems at hip prosthesis interfaces”. In:Journal of Applied Clinical Medical Physics18.3 (May 2017), pp. 9–15.DOI: 10.1002/acm2. 12060
-
[3]
K. Latifi, J. Oliver, R. Baker, et al. “Study of 201 Non- Small Cell Lung Cancer Patients Given Stereotactic Ablative Radiation Therapy Shows Local Control De- pendence on Dose Calculation Algorithm”. In:Interna- tional Journal of Radiation Oncology*Biology*Physics 88.5 (Apr. 2014), pp. 1108–1113.DOI: 10.1016/j.ijrobp. 2013.12.047
-
[5]
F. Baldacci, A. Mittone, A. Bravin, et al. “A track length estimator method for dose calculations in low-energy X-ray irradiations: implementation, properties and per- formance”. In:Zeitschrift f ¨ur Medizinische Physik25.1 (Mar. 2015), pp. 36–47.DOI: 10.1016/j.zemedi.2014. 04.001
-
[6]
Geant4- based Monte Carlo simulations on GPU for medical applications
J. Bert, H. Perez-Ponce, Z. El Bitar, et al. “Geant4- based Monte Carlo simulations on GPU for medical applications”. In:Physics in Medicine and Biology 58.16 (Aug. 21, 2013), pp. 5593–5611.DOI: 10.1088/ 0031-9155/58/16/5593
2013
-
[7]
GPUMCD: A new GPU-oriented Monte Carlo dose calculation plat- form
S. Hissoiny, B. Ozell, H. Bouchard, et al. “GPUMCD: A new GPU-oriented Monte Carlo dose calculation plat- form”. In:Medical Physics38.2 (Feb. 2011), pp. 754– 764.DOI: 10.1118/1.3539725
-
[8]
The strong coupling constant: state of the art and the decade ahead,
A. Behlouli, D. Visvikis, and J. Bert. “Improved Wood- cock tracking on Monte Carlo simulations for medical applications”. In:Physics in Medicine and Biology 63.22 (Nov. 9, 2018), p. 225005.DOI: 10.1088/1361- 6560/aae937
-
[9]
DeepDose: Towards a fast dose calculation engine for radiation therapy using deep learning
C. Kontaxis, G. Bol, J. Lagendijk, et al. “DeepDose: Towards a fast dose calculation engine for radiation therapy using deep learning”. In:Physics in Medicine & Biology65.7 (2020), p. 075013
2020
-
[10]
Deep learning- based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy
X. Zhang, H. Zhang, J. Wang, et al. “Deep learning- based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy”. In:Medical Physics50.12 (2023), pp. 7314–7323
2023
-
[11]
Deep-dose: a voxel dose estimation method using deep convolutional neural network for personalized internal dosimetry
M. S. Lee, D. Hwang, J. H. Kim, et al. “Deep-dose: a voxel dose estimation method using deep convolutional neural network for personalized internal dosimetry”. In: Scientific reports9.1 (2019), p. 10308
2019
-
[12]
Fast Monte Carlo- Based Inverse Planning for Prostate Brachytherapy by Using Deep Learning
M. Villa, J. Bert, A. Valeri, et al. “Fast Monte Carlo- Based Inverse Planning for Prostate Brachytherapy by Using Deep Learning”. In:IEEE Transactions on Ra- diation and Plasma Medical Sciences6.2 (Feb. 2022), pp. 182–188.DOI: 10.1109/TRPMS.2021.3060191
-
[13]
Fast dose cal- culation in x-ray guided interventions by using deep learning
M. Villa, B. Nasr, D. Benoit, et al. “Fast dose cal- culation in x-ray guided interventions by using deep learning”. In:Physics in Medicine & Biology68.16 (2023), p. 164001
2023
-
[14]
An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
A. Dosovitskiy. “An image is worth 16x16 words: Transformers for image recognition at scale”. In:arXiv preprint arXiv:2010.11929(2020)
work page internal anchor Pith review Pith/arXiv arXiv 2010
-
[15]
Unetr: Transformers for 3d medical image segmentation
A. Hatamizadeh, Y . Tang, V . Nath, et al. “Unetr: Transformers for 3d medical image segmentation”. In: Proceedings of the IEEE/CVF winter conference on applications of computer vision. 2022, pp. 574–584
2022
-
[16]
Sub- second photon dose prediction via transformer neural networks
O. Pastor-Serrano, P. Dong, C. Huang, et al. “Sub- second photon dose prediction via transformer neural networks”. In:Medical physics50.5 (2023), pp. 3159– 3171
2023
-
[17]
Concur- rent spatial and channel ‘squeeze & excitation’in fully convolutional networks
A. G. Roy, N. Navab, and C. Wachinger. “Concur- rent spatial and channel ‘squeeze & excitation’in fully convolutional networks”. In:International conference on medical image computing and computer-assisted intervention. Springer. 2018, pp. 421–429
2018
-
[18]
Swin unetr: Swin transformers for semantic segmentation of brain tumors in mri images
A. Hatamizadeh, V . Nath, Y . Tang, et al. “Swin unetr: Swin transformers for semantic segmentation of brain tumors in mri images”. In:International MICCAI brain- lesion workshop. Springer. 2021, pp. 272–284
2021
-
[19]
Swinunetr-v2: Stronger swin transformers with stagewise convolutions for 3d medical image segmentation
Y . He, V . Nath, D. Yang, et al. “Swinunetr-v2: Stronger swin transformers with stagewise convolutions for 3d medical image segmentation”. In:International Con- ference on Medical Image Computing and Computer- Assisted Intervention. Springer. 2023, pp. 416–426
2023
-
[20]
R. F. Thompson, A. Kanwar, B. Merz, et al.Stress- Testing Pelvic Autosegmentation Algorithms Using Anatomical Edge Cases (Prostate-Anatomical-Edge- Cases). Version 1. 2023.DOI: 10.7937/QSTF-ST65
-
[21]
D. Sarrut, N. Arbor, T. Baudier, et al.GATE 10 Monte Carlo particle transport simulation – Part I: develop- ment and new features. Version Number: 2. 2025.DOI: 10.48550/ARXIV .2507.09842
work page internal anchor Pith review doi:10.48550/arxiv 2025
-
[22]
Monte Carlo modeling of a Novalis TX Varian 6 MV with HD-120 multileaf collimator
L. A. Vazquez-Quino, B. Massingill, C. Shi, et al. “Monte Carlo modeling of a Novalis TX Varian 6 MV with HD-120 multileaf collimator”. In:Journal of Applied Clinical Medical Physics13.5 (Sept. 2012), pp. 300–313.DOI: 10.1120/jacmp.v13i5.3960
-
[23]
U-net: Convo- lutional networks for biomedical image segmentation
O. Ronneberger, P. Fischer, and T. Brox. “U-net: Convo- lutional networks for biomedical image segmentation”. In:International Conference on Medical image comput- ing and computer-assisted intervention. Springer. 2015, pp. 234–241
2015
-
[24]
3D U-Net: learning dense volumetric segmentation from sparse annotation
¨O. C ¸ ic ¸ek, A. Abdulkadir, S. S. Lienkamp, et al. “3D U-Net: learning dense volumetric segmentation from sparse annotation”. In:International conference on medical image computing and computer-assisted inter- vention. Springer. 2016, pp. 424–432
2016
-
[25]
Real-time patient- specific CT dose estimation using a deep convolutional neural network
J. Maier, E. Eulig, S. Dorn, et al. “Real-time patient- specific CT dose estimation using a deep convolutional neural network”. In:2018 IEEE Nuclear Science Sym- posium and Medical Imaging Conference Proceedings (NSS/MIC). IEEE. 2018, pp. 1–3
2018
-
[26]
3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture
D. Nguyen, X. Jia, D. Sher, et al. “3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture”. In:Physics in medicine & Biology64.6 (2019), p. 065020. 13
2019
-
[27]
Deep dose plu- gin: towards real-time Monte Carlo dose calculation through a deep learning-based denoising algorithm
T. Bai, B. Wang, D. Nguyen, et al. “Deep dose plu- gin: towards real-time Monte Carlo dose calculation through a deep learning-based denoising algorithm”. In: Machine Learning: Science and Technology2.2 (2021), p. 025033
2021
-
[28]
Real-time estimation of patient-specific dose distributions for medical CT using the deep dose estimation
J. Maier, L. Klein, E. Eulig, et al. “Real-time estimation of patient-specific dose distributions for medical CT using the deep dose estimation”. In:Medical physics 49.4 (2022), pp. 2259–2269
2022
-
[29]
Instance Normalization: The Missing Ingredient for Fast Stylization
D. Ulyanov, A. Vedaldi, and V . Lempitsky. “Instance normalization: The missing ingredient for fast styliza- tion”. In:arXiv preprint arXiv:1607.08022(2016)
work page Pith review arXiv 2016
-
[30]
High- particle simulation of monte-carlo dose distribution with 3D convlstms
S. Martinot, N. Bus, M. Vakalopoulou, et al. “High- particle simulation of monte-carlo dose distribution with 3D convlstms”. In:International Conference on Medi- cal Image Computing and Computer-Assisted Interven- tion. Springer. 2021, pp. 499–508
2021
-
[31]
DeepMC: a deep learning method for efficient Monte Carlo beam- let dose calculation by predictive denoising in mag- netic resonance-guided radiotherapy
R. Neph, Q. Lyu, Y . Huang, et al. “DeepMC: a deep learning method for efficient Monte Carlo beam- let dose calculation by predictive denoising in mag- netic resonance-guided radiotherapy”. In:Physics in Medicine & Biology66.3 (2021), p. 035022
2021
-
[32]
Deep learning-based prediction of Monte Carlo dose distribution for heavy ion therapy
R. He, H. Zhang, J. Wang, et al. “Deep learning-based prediction of Monte Carlo dose distribution for heavy ion therapy”. In:Physics and Imaging in Radiation Oncology34 (2025), p. 100735
2025
-
[33]
MCDNet–a denoising convolutional neural network to accelerate Monte Carlo radiation transport simulations: A proof of principle with patient dose from x-ray CT imaging
Z. Peng, H. Shan, T. Liu, et al. “MCDNet–a denoising convolutional neural network to accelerate Monte Carlo radiation transport simulations: A proof of principle with patient dose from x-ray CT imaging”. In:Ieee Access7 (2019), pp. 76680–76689
2019
-
[34]
A novel multichannel deep learning model for fast denoising of Monte Carlo dose calculations: preclinical applica- tions
R. H. van Dijk, N. Staut, C. J. Wolfs, et al. “A novel multichannel deep learning model for fast denoising of Monte Carlo dose calculations: preclinical applica- tions”. In:Physics in Medicine & Biology67.16 (2022), p. 164001
2022
-
[35]
Accurate and versatile 3D segmentation of plant tissues at cellular resolution
A. Wolny, L. Cerrone, A. Vijayan, et al. “Accurate and versatile 3D segmentation of plant tissues at cellular resolution”. In:Elife9 (2020), e57613
2020
-
[36]
Superhuman accuracy on the SNEMI3D connectomics challenge
K. Lee, J. Zung, P. Li, et al. “Superhuman accuracy on the SNEMI3D connectomics challenge”. In:arXiv preprint arXiv:1706.00120(2017)
-
[37]
A plan verification platform for online adaptive proton therapy using deep learning-based Monte–Carlo denoising
G. Zhang, X. Chen, J. Dai, et al. “A plan verification platform for online adaptive proton therapy using deep learning-based Monte–Carlo denoising”. In:Physica Medica103 (2022), pp. 18–25
2022
-
[38]
AnatomyNet: deep learning for fast and fully automated whole-volume segmentation of head and neck anatomy
W. Zhu, Y . Huang, L. Zeng, et al. “AnatomyNet: deep learning for fast and fully automated whole-volume segmentation of head and neck anatomy”. In:Medical physics46.2 (2019), pp. 576–589
2019
-
[39]
Squeeze-and-excitation networks
J. Hu, L. Shen, and G. Sun. “Squeeze-and-excitation networks”. In:Proceedings of the IEEE conference on computer vision and pattern recognition. 2018, pp. 7132–7141
2018
-
[40]
Swin transformer: Hier- archical vision transformer using shifted windows
Z. Liu, Y . Lin, Y . Cao, et al. “Swin transformer: Hier- archical vision transformer using shifted windows”. In: Proceedings of the IEEE/CVF international conference on computer vision. 2021, pp. 10012–10022
2021
-
[41]
TransUNet: Transformers Make Strong Encoders for Medical Image Segmentation
J. Chen, Y . Lu, Q. Yu, et al. “Transunet: Transformers make strong encoders for medical image segmentation”. In:arXiv preprint arXiv:2102.04306(2021)
work page internal anchor Pith review arXiv 2021
-
[42]
3d transunet: Advancing medical image segmentation through vision transform- ers. arXiv 2023
J. Chen, J. Mei, X. Li, et al. “3d transunet: Advancing medical image segmentation through vision transform- ers. arXiv 2023”. In:arXiv preprint arXiv:2310.07781 (2023)
-
[43]
Swin-unet: Unet- like pure transformer for medical image segmentation
H. Cao, Y . Wang, J. Chen, et al. “Swin-unet: Unet- like pure transformer for medical image segmentation”. In:European conference on computer vision. Springer. 2022, pp. 205–218
2022
-
[44]
SegFormer: Simple and efficient design for semantic segmentation with trans- formers
E. Xie, W. Wang, Z. Yu, et al. “SegFormer: Simple and efficient design for semantic segmentation with trans- formers”. In:Advances in neural information processing systems34 (2021), pp. 12077–12090
2021
-
[45]
Mitigating inherent noise in Monte Carlo dose distributions us- ing dilated U-Net
U. Javaid, K. Souris, D. Dasnoy, et al. “Mitigating inherent noise in Monte Carlo dose distributions us- ing dilated U-Net”. In:Medical Physics46.12 (2019), pp. 5790–5798
2019
-
[46]
Single shot full plan deep learning dose computation for radiation therapy using spherical harmonics
M. F. Kraus, R. Gao, S. Arberet, et al. “Single shot full plan deep learning dose computation for radiation therapy using spherical harmonics”. In:Medical Physics 53.1 (2026), e70223
2026
-
[47]
Differentiable Gamma Index-Based Loss Functions: Accelerating Monte-Carlo Radiotherapy Dose Simula- tion
S. Martinot, N. Komodakis, M. Vakalopoulou, et al. “Differentiable Gamma Index-Based Loss Functions: Accelerating Monte-Carlo Radiotherapy Dose Simula- tion”. In:International Conference on Information Pro- cessing in Medical Imaging. Springer. 2023, pp. 485– 496
2023
-
[48]
Project monai
M. Consortium et al. “Project monai”. In:Zenodo (2020)
2020
-
[49]
Tomotherapy treatment plan quality assurance: the impact of applied criteria on passing rate in gamma index method
S. Bresciani, A. D. Dia, A. Maggio, et al. “Tomotherapy treatment plan quality assurance: the impact of applied criteria on passing rate in gamma index method”. In: Medical physics40.12 (2013), p. 121711
2013
-
[50]
Gamma anal- ysis dependence on specified low-dose thresholds for VMAT QA
J.-H. Song, M.-J. Kim, S.-H. Park, et al. “Gamma anal- ysis dependence on specified low-dose thresholds for VMAT QA”. In:Journal of Applied Clinical Medical Physics16.6 (2015), pp. 263–272
2015
-
[51]
To- talSegmentator: robust segmentation of 104 anatomic structures in CT images
J. Wasserthal, H.-C. Breit, M. T. Meyer, et al. “To- talSegmentator: robust segmentation of 104 anatomic structures in CT images”. In:Radiology: Artificial In- telligence5.5 (2023), e230024
2023
-
[52]
PlatiPy: processing library and analysis toolkit for medical imaging in Python
P. Chlap and R. N. Finnegan. “PlatiPy: processing library and analysis toolkit for medical imaging in Python”. In:Journal of Open Source Software8.86 (2023), p. 5374
2023
-
[53]
Current and emerging trends in medical image seg- mentation with deep learning
P.-H. Conze, G. Andrade-Miranda, V . K. Singh, et al. “Current and emerging trends in medical image seg- mentation with deep learning”. In:IEEE Transactions on Radiation and Plasma Medical Sciences7.6 (2023), pp. 545–569
2023
-
[54]
A review on low-dose emission tomography post-reconstruction denoising with neural network approaches
A. Bousse, V . S. S. Kandarpa, K. Shi, et al. “A review on low-dose emission tomography post-reconstruction denoising with neural network approaches”. In:IEEE transactions on radiation and plasma medical sciences 8.4 (2024), pp. 333–347
2024
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.