Pith. sign in

REVIEW 1 cited by

Ground Calibration Result of the Wide-field X-ray Telescope (WXT) onboard the Einstein Probe

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2505.18939 v1 pith:7ZRS4MXZ submitted 2025-05-25 astro-ph.IM astro-ph.HEhep-exphysics.ins-det

Ground Calibration Result of the Wide-field X-ray Telescope (WXT) onboard the Einstein Probe

classification astro-ph.IM astro-ph.HEhep-exphysics.ins-det
keywords calibrationx-rayrangeeffectiveenergyresultsarcminarea
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

We report on results of the on-ground X-ray calibration of the Wide-field X-ray Telescope (WXT) built from novel lobster-eye micro-pore optics, onboard the Einstein Probe (EP) satellite. To fully characterize the instrumental performance and properties, a series of tests and calibrations have been carried out at different levels of devices, assemblies and the complete module before the launch of EP. In this paper, we present the calibration results of three flight model modules (FM1, FM5 and FM11) obtained during their end-to-end module calibration experiments carried out at the 100-m X-ray Test Facility (100XF) of IHEP, CAS. Measurements of the Point Spread Function (PSF), effective area, and energy response were performed for multiple incident directions and several characteristic X-ray emission line energies. Specifically, the distributions of the PSF and effective areas are found to be roughly uniform across the FoV, in large agreement with the prediction of lobster-eye optics. Their energy dependence behavior aligns well with theoretical predictions and Monte Carlo simulations. At 1.25 keV, the full width at half maximum (FWHM) of the focal spot is in range of 3-7 arcmin (a median of 4.2) and the effective area in range of 2-3 $cm^2$. Noticeably, the flight model instruments demonstrate a $\sim1.5$ arcmin spatial resolution improvement over the previously launched Lobster Eye Imager for Astronomy. The properties of the complementary metal-oxide semiconductor (CMOS) sensors were also calibrated. The gain coefficients are in range of 6.4-6.9 eV/DN. The energy resolutions are in range of 120-140 eV at 1.25 keV, meeting design requirements. These calibration results have been ingested into the first version of calibration database (CALDB) and applied to the analysis of the scientific data acquired by WXT after the launch of EP.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. X-rays breaking out of pre-explosion ejecta mark a supernova's first light

    astro-ph.HE 2026-06 unverdicted novelty 6.0

    Detection of a thermal X-ray shock-breakout event from pre-explosion ejecta of a stripped massive star, indicating abrupt mass loss within a month of core collapse.