Automated multi-dataset INST ¹³C metabolic flux analysis at microliter scale reveals robust fluxes but variable metabolite pools in Corynebacterium~glutamicum
Pith reviewed 2026-06-29 22:36 UTC · model grok-4.3
The pith
Multi-dataset INST 13C-MFA at microliter scale yields robust fluxes but variable metabolite pools in C. glutamicum.
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
Core claim
Automated multi-dataset INST 13C-MFA performed at microliter scale with robotic liquid handling, rapid quenching, and LC-QToF-MS analytics enables joint estimation of fluxes and pool sizes from parallel ethanol-tracer experiments. Net fluxes prove robust across datasets and gain precision from the combined data, whereas pool-size estimates remain variable and do not converge under joint inference, revealing a methodological distinction from single-dataset analysis. The resulting flux map assigns a central role to the glyoxylate shunt during growth on the C2 substrate ethanol.
What carries the argument
Multi-dataset INST 13C-MFA that performs joint inference of fluxes and metabolite pool sizes across parallel tracer datasets generated by miniaturized robotic experiments.
If this is right
- Net intracellular fluxes can be determined with higher precision by combining multiple INST datasets than by analyzing any single dataset alone.
- Metabolite pool sizes estimated from single versus multi-dataset fits differ, indicating that pool-size inference is sensitive to the number and choice of labeling experiments.
- The glyoxylate shunt carries substantial flux during growth of the evolved C. glutamicum strain on ethanol.
- The miniaturized workflow produces flux maps at a fraction of the cost and time of conventional bioreactor INST 13C-MFA.
- The method supplies quantitative flux data suitable for iterative strain engineering cycles in biofoundries.
Where Pith is reading between the lines
- If pool sizes do not converge under joint inference, models that treat pools as fixed parameters may need re-examination for consistency across labeling conditions.
- The workflow could be extended to other substrates or organisms where stationary labeling yields low information content.
- Variable pool estimates may reflect real biological heterogeneity or unmodeled measurement offsets that future analytics improvements could resolve.
- High-throughput flux data at this scale could support automated model refinement loops that alternate between experiment and simulation within the same robotic platform.
Load-bearing premise
Datasets produced by the miniaturized quenching and analytics pipeline contain no scale-specific artifacts that would bias the joint pool-size estimates when the datasets are combined.
What would settle it
Repeating the multi-dataset analysis with an independent set of larger-volume experiments on the same strain and substrate and finding that pool-size estimates still fail to converge or that flux values shift systematically.
read the original abstract
Isotopically non-stationary metabolic flux analysis (INST $^{13}$C-MFA) provides unique insights into cellular physiology but is typically limited by low throughput and high experimental costs. Here, we present a miniaturized and automated workflow that integrates transient isotope labeling experiments with advanced computational modeling to enable parallel INST $^{13}$C-MFA at microliter scale. The approach is demonstrated for an evolved $Corynebacterium~glutamicum$ strain capable of efficient growth on ethanol, a substrate for which isotopically stationary $^{13}$C-MFA is inherently limited due to low labeling diversity. Using robotic liquid handling, rapid hot isopropanol quenching, and LC-QToF-MS-based analytics, highly informative datasets were generated from parallel 48-well experiments with different ethanol tracers. Multi-dataset INST $^{13}$C-MFA unlocked joint estimation of intracellular fluxes and metabolite pool sizes and significantly improved flux precision compared to single-dataset analyses. While net fluxes were robust across datasets, pool size estimates exhibited variability and did not converge under joint inference, highlighting a fundamental methodological difference to single-dataset INST $^{13}$C-MFA. The resulting multi-dataset flux map reveals a central role of the glyoxylate shunt during growth on ethanol, consistent with metabolic adaption to C2-based substrate utilization. Overall, this work demonstrates that automated multi-dataset INST $^{13}$C-MFA is technically feasible and provides high-quality flux analysis at a fraction of the cost of conventional lab-scale bioreactor-based approaches. The presented workflow establishes a scalable framework for high-throughput quantitative fluxomics in microbial biotechnology and supports integration into iterative strain engineering and biofoundry pipelines.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript describes a miniaturized, robotic workflow for parallel INST 13C-MFA experiments at microliter scale in 48-well plates, using hot isopropanol quenching and LC-QToF-MS analytics on an evolved Corynebacterium glutamicum strain growing on ethanol. Multiple ethanol tracers are employed to generate datasets that are then jointly fitted, yielding intracellular fluxes and metabolite pool sizes. The central claims are that multi-dataset fitting improves flux precision relative to single-dataset analyses, that net fluxes remain robust across datasets, and that metabolite pool sizes exhibit variability and fail to converge under joint inference, while the resulting flux map shows a prominent glyoxylate shunt consistent with C2-substrate adaptation. The workflow is positioned as a scalable, low-cost alternative to conventional bioreactor-based INST-MFA.
Significance. If the joint multi-dataset inference is free of scale-dependent bias, the approach would represent a meaningful advance in throughput for quantitative fluxomics, enabling integration into biofoundry pipelines. The reported robustness of net fluxes across independent tracer datasets is a positive indicator of internal consistency. However, the absence of any orthogonal validation for absolute pool-size estimates limits the strength of the claim that variability reflects a fundamental methodological difference rather than measurement artifact.
major comments (2)
- [Abstract / Results (multi-dataset fitting)] The claim that multi-dataset INST 13C-MFA 'significantly improved flux precision' and that pool sizes 'exhibited variability and did not converge' (Abstract) rests on the untested premise that the 48-well robotic quenching and LC-QToF-MS datasets can be combined without introducing systematic offsets in absolute concentrations. No cross-validation of pool sizes against an orthogonal assay, larger-scale bioreactor controls, or internal standards that would isolate quenching-volume or matrix effects is described; because INST-MFA pool-size identifiability is known to be sensitive to absolute scaling, this omission directly affects the interpretation of both the precision gain and the reported non-convergence.
- [Methods (quenching and analytics) / Results (pool-size estimates)] The manuscript states that the miniaturized workflow produces 'highly informative datasets' that can be directly used for joint estimation, yet provides no quantitative assessment (e.g., recovery of known pool sizes from spiked standards or comparison of labeling dynamics at different culture volumes) to rule out scale-specific artifacts in the quenching or ionization steps. This is load-bearing for the assertion that the observed pool-size variability is biological rather than methodological.
minor comments (2)
- [Methods (computational modeling)] Notation for the joint objective function and weighting of the multiple tracer datasets should be made explicit; it is currently unclear how the different labeling time courses are combined in the parameter estimation.
- [Figures] Figure legends should report the number of biological replicates and the exact number of independent tracer experiments included in the multi-dataset fits.
Simulated Author's Rebuttal
We thank the referee for the careful reading and constructive critique. The comments correctly identify that our claims regarding metabolite pool-size variability rest on an assumption of dataset combinability that lacks explicit orthogonal validation. We address each point below and will revise the manuscript accordingly.
read point-by-point responses
-
Referee: [Abstract / Results (multi-dataset fitting)] The claim that multi-dataset INST 13C-MFA 'significantly improved flux precision' and that pool sizes 'exhibited variability and did not converge' (Abstract) rests on the untested premise that the 48-well robotic quenching and LC-QToF-MS datasets can be combined without introducing systematic offsets in absolute concentrations. No cross-validation of pool sizes against an orthogonal assay, larger-scale bioreactor controls, or internal standards that would isolate quenching-volume or matrix effects is described; because INST-MFA pool-size identifiability is known to be sensitive to absolute scaling, this omission directly affects the interpretation of both the precision gain and the reported non-convergence.
Authors: We agree that the absence of orthogonal validation for absolute pool sizes limits the strength of interpreting the observed non-convergence as a fundamental methodological difference rather than a possible measurement artifact. The robustness of net fluxes across independent tracer datasets remains the primary internal consistency check. In the revised manuscript we will (i) qualify the Abstract and Results statements on pool-size variability to note that absolute scaling was not independently validated, (ii) emphasize that the reported precision gain applies specifically to flux estimates, and (iii) add a limitations paragraph discussing potential scale-dependent quenching or ionization effects. revision: partial
-
Referee: [Methods (quenching and analytics) / Results (pool-size estimates)] The manuscript states that the miniaturized workflow produces 'highly informative datasets' that can be directly used for joint estimation, yet provides no quantitative assessment (e.g., recovery of known pool sizes from spiked standards or comparison of labeling dynamics at different culture volumes) to rule out scale-specific artifacts in the quenching or ionization steps. This is load-bearing for the assertion that the observed pool-size variability is biological rather than methodological.
Authors: The referee is correct; no spiked-standard recovery or cross-volume labeling comparison is reported. Because such experiments would require additional wet-lab work outside the current dataset, we cannot supply them in revision. We will instead revise the text to remove any implication that pool-size variability is necessarily biological and will explicitly state that the joint-inference results for pool sizes should be interpreted with caution pending future absolute-quantification controls. revision: partial
- Quantitative validation of absolute pool-size recovery (spiked standards or bioreactor comparison) is absent from the existing experimental record and cannot be generated without new experiments.
Circularity Check
No circularity; claims rest on experimental data comparison
full rationale
The manuscript describes an automated experimental workflow for generating INST 13C-MFA datasets at microliter scale and reports empirical outcomes from single- versus multi-dataset fitting. No derivation chain, fitted-parameter prediction, or self-citation load-bearing step is present; net-flux robustness and pool-size variability are direct outputs of the joint inference on measured labeling and concentration data. The central result (improved flux precision under joint estimation) is therefore falsifiable against the raw datasets and does not reduce to any input by construction.
Axiom & Free-Parameter Ledger
axioms (2)
- domain assumption Metabolic network is at metabolic steady state during the transient labeling experiment
- domain assumption Quenching and extraction preserve intracellular metabolite pools without scale-dependent bias
Reference graph
Works this paper leans on
-
[1]
J. Nießer, M. F. Müller, J. Kappelmann, W. Wiechert, and S. Noack. Hot isopropanol quenching procedure for automated microtiter plate scale 13 C-labeling experiments . Microb. Cell Fact., 21: 0 78, 2022. doi:10.1186/s12934-022-01806-4
-
[2]
K. N \" o h, S. Niedenf \" u hr, M. Bey , and W. Wiechert. A Pareto approach to resolve the conflict between information gain and experimental costs: Multiple-criteria design of carbon labeling experiments . PLOS Comput. Biol., 14: 0 e1006533, 2018. doi:10.1371/journal.pcbi.1006533
-
[3]
Y. Yuan, T. Hoon Yang , and E. Heinzle. 13 C metabolic flux analysis for larger scale cultivation using gas chromatography-combustion-isotope ratio mass spectrometry . Metab. Eng., 12: 0 392--400, 2010. doi:10.1016/j.ymben.2010.02.001
-
[4]
S. Bachleitner, O. Ata, and D. Mattanovich. The potential of CO _2 -based production cycles in biotechnology to fight the climate crisis. Nat. Commun., 14: 0 6978, 2023. doi:10.1038/s41467-023-42790-6
-
[5]
M. Bey , S. Azzouzi, M. Weitzel, W. Wiechert, and K. N \" o h. The design of FluxML: A universal modeling language for 13 C metabolic flux analysis . Front. Microbiol., 10, 2019. doi:10.3389/fmicb.2019.01022
-
[6]
P. Droste, K. N \" o h, and W. Wiechert. Omix -- a visualization tool for metabolic networks with highest usability and customizability in focus . Chem. Ing. Tech., 85: 0 849--862, 2013. doi:10.1002/cite.201200234
-
[7]
A. Drysch, M. El Massaoudi, C. Mack, R. Takors, A. A. de Graaf, and H. Sahm. Production process monitoring by serial mapping of microbial carbon flux distributions using a novel sensor reactor approach: II -- 13 C -labeling-based metabolic flux analysis and l- L ysine production. Metab. Eng., 5: 0 96--107, 2003. doi:10.1016/S1096-7176(03)00005-3
-
[8]
L. Eggeling and M. Bott. Handbook of Corynebacterium glutamicum . CRC Press, 2005. doi:10.1201/9781420039696
-
[10]
A. Fina, P. Millard, J. Albiol, P. Ferrer, and S. Heux. High throughput 13 C-metabolic flux analysis of 3-hydroxypropionic acid producing Pichia pastoris reveals limited availability of acetyl-CoA and ATP due to tight control of the glycolytic flux . Microb. Cell Fact., 22, 2023. doi:10.1186/s12934-023-02123-0
-
[11]
Fritzson
P. Fritzson. Modelica: Equation-based, object-oriented modelling of physical systems. In Foundations of Multi-Paradigm Modelling for Cyber-Physical Systems, pages 45--96. Springer International Publishing, 2020
2020
-
[12]
L. Halle, N. Hollmann, N. Tenhaef, L. Mbengi, C. Glitz, W. Wiechert, T. Polen, M. Baumgart, M. Bott, and S. Noack. Robotic workflows for automated long-term adaptive laboratory evolution: I mproving ethanol utilization by Corynebacterium glutamicum. Microb. Cell Fact., 22: 0 175, 2023. doi:10.1186/s12934-023-02180-5
-
[13]
P. Heinrich, C. Kohler, L. Ellmann, P. Kuerner, R. Spang, P. J. Oefner, and K. Dettmer. Correcting for natural isotope abundance and tracer impurity in MS-, MS/MS- and high-resolution-multiple-tracer-data from stable isotope labeling experiments with IsoCorrectoR . Scientific Reports, 8: 0 17910, 2018. doi:10.1038/s41598-018-36293-4
-
[14]
J. Hemmerich, N. Tenhaef, C. Steffens, J. Kappelmann, M. Weiske, S. J. Reich, W. Wiechert, M. Oldiges, and S. Noack. Less sacrifice, more insight: Repeated low-volume sampling of microbioreactor cultivations enables accelerated deep phenotyping of microbial strain libraries. J. Biotechnol., 14: 0 e1800428, 2019. doi:10.1002/biot.201800428
-
[15]
J. Hemmerich, N. Tenhaef, W. Wiechert, and S. Noack. pyFOOMB : Python framework for object oriented modeling of bioprocesses. Eng. Life Sci., 21: 0 242--257, 2021. doi:10.1002/elsc.202000088
-
[16]
S. Heux, J. Poinot, S. Massou, S. Sokol, and J. C. Portais. A novel platform for automated high-throughput fluxome profiling of metabolic variants. Metab. Eng., 25: 0 8--19, 2014. doi:10.1016/j.ymben.2014.06.001
-
[17]
C. Jungreuthmayer, S. Neubauer, T. Mairinger, J. Zanghellini, and S. Hann. ICT: isotope correction toolbox . Bioinformatics, 32: 0 154--156, 2015. doi:10.1093/bioinformatics/btv514
-
[18]
M. Kanehisa and S. Goto. KEGG : kyoto encyclopedia of genes and genomes. Nucleic Acids Res., 28: 0 27--30, 2000. doi:10.1093/nar/27.1.29
-
[19]
J. Kappelmann, W. Wiechert, and S. Noack. Cutting the Gordian Knot: Identifiability of anaplerotic reactions in Corynebacterium glutamicum by means of 13 C-metabolic flux analysis . Biotechnol. Bioeng., 113: 0 661--674, 2016. doi:10.1002/bit.25833
-
[20]
J. Kappelmann, B. Klein, P. Geilenkirchen, and S. Noack. Comprehensive and accurate tracking of carbon origin of LC-tandem mass spectrometry collisional fragments for 13 C-MFA . Anal. Bioanal. Chem., 409: 0 2309--2326, 2017. doi:10.1007/s00216-016-0174-9
-
[21]
C. Keilhauer, L. Eggeling, and H. Sahm. Isoleucine synthesis in Corynebacterium glutamicum: Molecular analysis of the ilvb-ilvn-ilvc operon. J. Bacteriol., 175, 1993. doi:10.1128/jb.175.17.5595-5603.1993
-
[22]
Z. A. King, A. Dräger, A. Ebrahim, N. Sonnenschein, N. E. Lewis, and B. O. Palsson. Escher: A web application for building, sharing, and embedding data-rich visualizations of biological pathways. PLOS Comput. Biol., 11: 0 1--13, 2015. doi:10.1371/journal.pcbi.1004321
-
[23]
Z. A. King, J. Lu, A. Dräger, P. Miller, S. Federowicz, J. A. Lerman, A. Ebrahim, B. O. Palsson, and N. E. Lewis. BiGG models: A platform for integrating, standardizing and sharing genome-scale models. Nucleic Acids Res., 44: 0 D515--D522, 2016. doi:10.1093/nar/gkv1049
-
[24]
K. R. Kjeldsen and J. Nielsen. In silico genome-scale reconstruction and validation of the Corynebacterium glutamicum metabolic network. Biotechnol. Bioeng., 102: 0 583--597, 2009. doi:10.1002/bit.22067
-
[25]
E. Kurpejović, B. Sariyar Akbulut, and F. G. Avci. Tailoring Corynebacterium glutamicum for sustainable biomanufacturing: From traditional to cutting-edge technologies. Mol. Biotechnol., 68: 0 1106--1126, 2025. doi:10.1007/s12033-025-01447-z
-
[26]
Latour, D
T. Latour, D. Strohmeier, M. Osthege, W. Wiechert, and S. Noack. estim8 -- An FMI-compliant Python toolbox for bioprocess modeling and parameter estimation . J. Open Source Software, (submitted), unpublished
-
[27]
L. Le Gr \' e gam , Y. Guitton, F. Bellvert, S. Heux, F. Jourdan, J.-C. Portais, and P. Millard. PhysioFit: A software to quantify cell growth parameters and extracellular fluxes . Bioinformatics, 40, 2024. doi:10.1093/bioinformatics/btae488
-
[28]
R. W. Leighty and M. R. Antoniewicz. COMPLETE-MFA: Complementary parallel labeling experiments technique for metabolic flux analysis . Metab. Eng., 20: 0 49--55, 2013. doi:10.1016/j.ymben.2013.08.006
-
[29]
J. Liu, X. Zhao, H. Cheng, Y. Guo, X. Ni, L. Wang, G. Sun, X. Wen, J. Chen, J. Wang, J. An, X. Guo, Z. Shi, H. Li, R. Wang, M. Zhao, X. Liao, Y. Wang, P. Zheng, M. Wang, and J. Sun. Comprehensive screening of industrially relevant components at genome scale using a high-quality gene overexpression collection of Corynebacterium glutamicum. Trends Biotechno...
-
[30]
C. P. Long and M. R. Antoniewicz. High-resolution 13 C metabolic flux analysis . Nat. Protoc., 14: 0 2856--2877, 2019. doi:10.1038/s41596-019-0204-0
-
[31]
J. Marienhagen. Engineering of Corynebacterium glutamicum for the synthesis of aromatic compounds. Appl. Microbiol. Biotechnol., 109: 0 132, 2025. doi:10.1007/s00253-025-13520-3
-
[32]
S. Niedenf \" u hr, W. Wiechert, and K. N \" o h. How to measure metabolic fluxes: A taxonomic guide for 13 C fluxomics . Curr. Opin. Biotechnol., 34: 0 82--90, 2015. doi:10.1016/j.copbio.2014.12.003
-
[33]
u hr, A. ten Pierick, P. T. van Dam, C. A. Suarez-Mendez, K. N \
S. Niedenf \" u hr, A. ten Pierick, P. T. van Dam, C. A. Suarez-Mendez, K. N \" o h, and S. A. Wahl. Natural isotope correction of MS/MS measurements for metabolomics and 13 C fluxomics . Biotechnol. Bioeng., 113: 0 1137--1147, 2016. doi:10.1002/bit.25859
-
[34]
J. Nielsen. It is all about metabolic fluxes . J. Bacteriol., 185: 0 7031--7035, 2003. doi:10.1128/JB.185.24.7031-7035.2003
-
[35]
J. Nießer, M. Osthege, E. von Lieres, W. Wiechert, and S. Noack. PeakPerformance -- a tool for Bayesian inference-based fitting of LC-MS/MS peaks . J. Open Source Softw., 9: 0 7313, 2024. doi:10.21105/joss.07313
-
[36]
S. Noack, R. Voges, J. Gätgens, and W. Wiechert. The linkage between nutrient supply, intracellular enzyme abundances and bacterial growth: New evidences from the central carbon metabolism of Corynebacterium glutamicum. J. Biotechnol., 258: 0 13--24, 2017. doi:10.1016/j.jbiotec.2017.06.407
-
[37]
K. N \" o h and W. Wiechert. The benefits of being transient: Isotope-based metabolic flux analysis at the short time scale . Appl. Microbiol. Biotechnol., 91: 0 1247--1265, 2011. doi:10.1007/s00253-011-3390-4
-
[38]
K. N \" o h, S. A. Wahl, and W. Wiechert. Computational tools for isotopically instationary 13 C labeling experiments under metabolic steady state conditions . Metab. Eng., 8: 0 554--577, 2006. doi:10.1016/j.ymben.2006.05.006
-
[39]
K. N \" o h, K. Gr \" o nke, B. Luo, R. Takors, M. Oldiges, and W. Wiechert. Metabolic flux analysis at ultra short time scale: Isotopically non-stationary 13 C labeling experiments . J. Biotechnol., 129: 0 249--267, 2007. doi:10.1016/j.jbiotec.2006.11.015
-
[40]
M. Osthege, N. Tenhaef, R. Zyla, C. Müller, J. Hemmerich, W. Wiechert, S. Noack, and M. Oldiges. bletl -- a python package for integrating BioLector microcultivation devices in the design-build-test-learn cycle. Eng. Life Sci., 22: 0 242--259, 2022. doi:10.1002/elsc.202100108
-
[41]
N. Paczia, A. Nilgen, T. Lehmann, J. Gätgens, W. Wiechert, and S. Noack. Extensive exometabolome analysis reveals extended overflow metabolism in various microorganisms. Microb. Cell Fact., 11: 0 122, 2012. doi:10.1186/1475-2859-11-122
-
[42]
R. D. Paul, J. F. Jadebeck, A. Stratmann, W. Wiechert, and K. Nöh. hopsy -- a methods marketplace for convex polytope sampling in P ython. Bioinformatics, 40, 2024. doi:10.1101/2023.12.22.573091
-
[43]
M. Rahim, M. Ragavan, S. Deja, M. E. Merritt, S. C. Burgess, and J. D. Young. INCA 2.0: A tool for integrated, dynamic modeling of NMR- and MS-based isotopomer measurements and rigorous metabolic flux analysis . Metab. Eng., 69: 0 275--285, 2022. doi:10.1016/j.ymben.2021.12.009
-
[44]
A. Reiter, L. Herbst, W. Wiechert, and M. Oldiges. Need for speed: E valuation of dilute and shoot-mass spectrometry for accelerated metabolic phenotyping in bioprocess development. Anal. Bioanal. Chem., 413: 0 3253--3268, 2021. doi:10.1007/s00216-021-03261-3
-
[45]
T. M. Rosch, J. Tenhaef, T. Stoltmann, T. Redeker, D. Kösters, N. Hollmann, K. Krumbach, W. Wiechert, M. Bott, S. Matamouros, J. Marienhagen, and S. Noack. Autobiotech -- a versatile biofoundry for automated strain engineering. ACS Synth. Biol., 13: 0 2227--2237, 2024. doi:10.1021/acssynbio.4c00298
-
[46]
U. Sauer. Metabolic networks in motion: 13 C-based flux analysis . Mol. Syst. Biol., 2: 0 62, 2006. doi:10.1038/msb4100109
-
[47]
S. Sokol, P. Millard, and J.-C. Portais. influx\_s: I ncreasing numerical stability and precision for metabolic flux analysis in isotope labelling experiments. Bioinformatics, 28: 0 687--693, 2012. doi:10.1093/bioinformatics/btr716
-
[48]
A. Stratmann, M. Bey , J. F. Jadebeck, W. Wiechert, and K. N \" o h. 13CFLUX -- third-generation high-performance engine for isotopically (non)stationary 13 C metabolic flux analysis . Bioinformatics, 44, 2025. doi:10.1093/bioinformatics/btaf630
-
[49]
A. Theorell, S. Leweke, W. Wiechert, and K. N \" o h. To be certain about the uncertainty: Bayesian statistics for ^ 13 C metabolic flux analysis . Biotechnol. Bioeng., 114: 0 2668--2684, 2017. doi:10.1002/bit.26379
-
[50]
A. Theorell, J. F. Jadebeck, W. Wiechert, J. McFadden, and K. Nöh. R ethinking 13 C-metabolic flux analysis – The Bayesian way of flux inference . Metab. Eng., 83: 0 137--149, 2024. doi:10.1016/j.ymben.2024.03.005
-
[51]
J. Tillack, N. Paczia, K. N\" o h, W. Wiechert, and S. Noack. Error propagation analysis for quantitative intracellular metabolomics. Metabolites, 2: 0 1012--30, 2012. doi:10.3390/metabo2041012
-
[52]
S. Unthan, A. Radek, W. Wiechert, M. Oldiges, and S. Noack. Bioprocess automation on a Mini Pilot Plant enables fast quantitative microbial phenotyping. Microb. Cell Fact., 14: 0 32, 2015. doi:10.1186/s12934-015-0216-6
-
[53]
A. W \"a chter and L. T. Biegler. On the implementation of an interior-point filter line-search algorithm for large-scale nonlinear programming. Math. Program., 106: 0 25--57, 2006. doi:10.1007/s10107-004-0559-y
-
[54]
V. F. Wendisch, A. A. De Graaf, H. Sahm, and B. J. Eikmanns. Quantitative determination of metabolic fluxes during coutilization of two carbon sources: Comparative analyses with Corynebacterium glutamicum during growth on acetate and/or glucose. J. Bacteriol., 182: 0 3088–3096, 2000. doi:10.1128/jb.182.11.3088-3096.2000
-
[55]
W. Wiechert, L. Helleckes, and K. N \" o h. Building trust in automated experimentation: Uncertainty quantification in the era of high-throughput biolabs. Curr. Opin. Biotechnol., 96: 0 1--9, 2025. doi:10.1016/j.copbio.2025.103382
-
[56]
B. G. Wong, C. P. Mancuso, S. Kiriakov, C. J. Bashor, and A. S. Khalil. Precise, automated control of conditions for high-throughput growth of yeast and bacteria with eVOLVER . Nat. Biotechnol., 36: 0 614--623, 2018. doi:10.1038/nbt.4151
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.