Pith. sign in

REVIEW

X-ray Monochromatic Imaging from Single-spectrum CT via Machine Learning

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2006.05841 v2 pith:TBDQXUQI submitted 2020-06-10 physics.med-ph eess.IV

X-ray Monochromatic Imaging from Single-spectrum CT via Machine Learning

classification physics.med-ph eess.IV
keywords monochromaticdectx-rayclinicalenergyimagingmodelsingle-spectrum
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

In clinical CT system, the x-ray tube emits polychromatic x-rays, and the x-ray detectors operate in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral equation. However, the non-linear model is not invertible with a computationally efficient solution, and is often approximated as a linear integral model in the form of the Radon transform. Such approximation basically ignores energy-dependent information and would generate beam hardening artifacts. Dual-energy CT (DECT) scans one object using two different x-ray energy spectra for the acquisition of two spectrally distinct projection datasets to improve imaging performance. Thus, DECT can reconstruct energy and material-selective images, realizing monochromatic imaging and material decomposition. Nevertheless, DECT would increase radiation dose, system complexity, and equipment cost relative to single-spectrum CT. In this paper, a machine-learning-based CT reconstruction method is proposed to perform monochromatic image reconstruction using a single-spectrum CT scanner. Specifically, a residual neural network (ResNet) model is adapted to map a CT image to a monochromatic counterpart at a pre-specified energy level. This ResNet is trained on clinical dual-energy data, showing an excellent convergence to a minimal loss. The trained network produces high-quality monochromatic images on testing data, with a relative error of less than 0.2%. This work has great potential in clinical DECT applications such as tissue characterization, beam hardening correction and proton therapy planning.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.